+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron WLCAL5-N Limit Switch

Omron WLCAL5-N is a WL Series limit switch with a rod spring lever actuator and screw terminals using a G½ conduit. The model is specified without an operation indicator and has a pretravel value of 15±5°. IP67 protection is listed, together with 25 mΩ maximum initial contact resistance. The WLCAL5-N belongs to the WL Series within the rod spring lever limit switch range from Omron. Its rod spring lever, G½ screw-terminal connection, no-indicator configuration, and 15±5° pretravel provide the core product identity. These specifications help separate WLCAL5-N from fork-lock, roller-lever, and plunger WL Series versions.

Omron WLCAL5-N Limit Switch
BrandOmron
ProductLimit Switch
Model NumberWLCAL5-N

Omron WLCAL5-N Limit Switch – Technical Specifications

SpecificationValue
Terminal ShapeScrew terminals (Conduit size: G½)
Pretravel Pt15±5°
IndicatorWithout operation indicator
Ambient Temperature-10 to +80°C (with no icing)
Ambient Humidity35 to 95%RH
Shock ResistanceDestruction: 1,000 m/s2 min. Malfunction: 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min. (at 500 VDC)
ActuatorRod spring lever
Vibration ResistanceMalfunction: 10 to 55 Hz, 1.5-mm double amplitude
Contact Resistance25 mΩ max. (initial value for the built-in switch)
Rated Frequency50/60 Hz

The Omron WLCAL5-N Limit Switch uses a rod spring lever actuator with screw terminals and a G½ conduit. It is specified without an operation indicator and has a pretravel value of 15±5°. IP67 protection is listed. Initial contact resistance is 25 mΩ maximum, while insulation resistance is 100 MΩ minimum at 500 VDC. Operating temperature ranges from -10 to 80°C with no icing, relative humidity is 35 to 95%, and frequency is 50/60 Hz. These specifications provide the secondary electrical and environmental data behind the rod-spring-lever actuator and G½ screw-terminal connection.

Malfunction vibration resistance is specified from 10 to 55 Hz at 1.5 mm double amplitude. Destructive shock resistance is 1,000 m/s² minimum and malfunction shock resistance is 300 m/s² minimum. WLCAL5-N is best identified by its WL Series designation, rod spring lever, G½ screw terminals, 15±5° pretravel, no-indicator configuration, IP67 protection, 25 mΩ initial contact resistance, and 100 MΩ insulation resistance. The source does not supply a separate normal current rating or contact form, so neither is inferred. These exact specifications give WLCAL5-N a clear product identity without introducing application or actuator-behaviour claims not present in the source. For another current WL Series lever model with G½ screw terminals and no operation indicator, see WLCA32-41-N.