Omron WLCL-2NLD-N Limit Switch
Omron WLCL-2NLD-N features an adjustable rod lever with a 25 to 140 mm range, screw terminals, and a G½ conduit entry. Its maximum pretravel is 20°, and an LED provides operation indication. The electrical data includes a 5 VDC, 1 mA resistive minimum load and an indicator supply range of 10 to 115 VAC/DC. IP67 protection, 100 MΩ minimum insulation resistance, and 25 mΩ maximum initial contact resistance are listed. The WLCL-2NLD-N belongs to the WL Series within the adjustable rod lever switch range from Omron limit switch products. Lever adjustment and LED indication are its key features.

| Brand | Omron |
| Product | Limit Switch |
| Model Number | WLCL-2NLD-N |
Omron WLCL-2NLD-N Limit Switch – Technical Specifications
| Specification | Value |
|---|---|
| Terminal Shape | Screw terminals (Conduit size: G½) |
| Pretravel Pt | 20° max. |
| Minimum Applicable Load | 5 VDC 1 mA, resistive load, P level |
| Rated Voltage | 10 to 115 VAC/DC |
| Leakage Current Reference Value | Approx. 0.4 mA at 10 VAC/DC Approx. 0.5 mA at 115 VAC/DC |
| Indicator | LED (With operation indicator) |
| Ambient Temperature | -10 to +80°C (with no icing) |
| Ambient Humidity | 35 to 95%RH |
| Shock Resistance | Destruction: 1,000 m/s2 min. Malfunction: 300 m/s2 min. |
| Degree Of Protection | IP67 |
| Insulation Resistance | 100 MΩ min. (at 500 VDC) |
| Actuator | Adjustable rod lever: (25 to 140 mm) |
| Vibration Resistance | Malfunction: 10 to 55 Hz, 1.5-mm double amplitude |
| Contact Resistance | 25 mΩ max. (initial value for the built-in switch) |
| Rated Frequency | 50/60 Hz |
The Omron WLCL-2NLD-N Limit Switch is fitted with an adjustable rod lever covering a 25 to 140 mm range. Connection is through screw terminals with a G½ conduit entry, while maximum pretravel is 20°. An LED operation indicator is provided. The minimum applicable load is listed as 5 VDC at 1 mA for a resistive load at P level, and the indicator circuit is specified from 10 to 115 VAC/DC. Approximate indicator current is 0.4 mA at 10 VAC/DC and 0.5 mA at 115 VAC/DC. IP67 protection is also specified.
Insulation resistance is 100 MΩ minimum at 500 VDC and initial contact resistance is 25 mΩ maximum. The switch operates from -10 to 80°C with relative humidity from 35 to 95%. Malfunction vibration resistance covers 10 to 55 Hz at 1.5 mm double amplitude, with shock resistance of 1,000 m/s² minimum for destruction and 300 m/s² minimum for malfunction. The adjustable rod length and LED are its strongest identifying details. For a flexible-rod WL model with LED indication, see the WLNJ-2LD-N.