ATS130N2C11LT: Schneider Altivar Soft Starter ATS130 105A

The ATS130N2C11LT is a robust soft starter from Schneider Electric, designed for heavy-duty motor applications under the Altivar ATS130 series.

BrandSchneider
Product TypeVFD(Variable Frequency Drive)
ProductATS130N2C11LT

Schneider Altivar Soft Starter ATS130 105A ATS130N2C11LT Technical Specifications:

SpecificationValue
Power supply frequency50...60 Hz +/- 5 Hz
Operating cycles/hour10 cyc/h
Maximum deflection under vibratory load (during transport)3 mm at 2-9 Hz
Maximum acceleration under vibratory load (during storage)10 m/s² at 9...200 Hz
Height197 mm
Relay output number1
Display type1 LED (green) for control power energized1 LED (yellow and red) for motor operation phases, errors
Pollution degreeLevel 2
Minimum motor current20 % Ie
Protection typePhase failure: mainsThermal protection: starterBypass error: starterControl voltage Us: starter
Package 1 Length28.000 cm
Maximum acceleration under vibrational stress (during operation)10 m/s² at 9...200 Hz
Environmental class (during operation)Without salt mist: 3C3 conforming to IEC 60721-3-33S3 conforming to IEC 60721-3-3
Suitable for mounting onto standard railsTRUE
Overload current profile300 % Ie for 5 s
[Uimp] rated impulse withstand voltage4 kV
Function availableDeceleration voltage rampBoost
Minimum switching current2.5 mA at 24 V DC for relay outputs
Operating altitude0...1000 m without derating1000...4000 m 1 % per 100 m
Package 1 Weight2.549 kg
Motor power hp30 hp at 200 V normal duty30 hp at 208 V normal duty40 hp at 230 V normal duty75 hp at 460 V normal duty75 hp at 480 V normal duty
IP degree of protectionIP20
Ambient air transport temperature-40…70 °C
Product or component typeSoft starter
Utilisation categoryAC-53A
Ue power supply voltage200...480 V - 15...10 %
Maximum switching currentOn resistive load for relay outputs : 1 A 250 V AC 400000 cyclesOn resistive load for relay outputs : 1 A 30 V DC 400000 cyclesOn inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cyclesOn inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles
Depth180 mm
Operating positionVertical +/- 30 degree
[Ui] rated insulation voltage480 V
Network number of phases3 phases
Input compatibilityDiscrete input level 1 PLC conforming to EN/IEC 61131-2
Device connectionIn line
Width81 mm
Torque controlFALSE
Ambient air temperature for storage-25…70 °C
Control power21.6 W starting and stopping3 W steady state
Range of productAltivar Soft Starter ATS130
[Uc] control circuit voltage24 V DC
Relative humidity5…95 % non condensing without dripping water conforming to IEC 60068-2-3
Power loss per device current dependent27 W
Net weight2.3 kg
[Ie] rated operational current105 A in line (at <40 °C)
Maximum deflection under vibratory load (during storage)3 mm at 2-9 Hz
Ambient air temperature for operation-10…40 °C (without derating)40…60 °C (with current derating of 2 % per °C)
Motor power kW30 kW at 230 V normal duty55 kW at 400 V normal duty55 kW at 440 V normal duty
Power loss static current independent3 W
Power loss during starting703 W 300 % Ie
Relay output typeRelay outputs R1A, R1C NO
Number of Units in Package 11

Built for performance, the Schneider ATS130N2C11LT offers a rated operational current of 105 A and a frequency range of 50–60 Hz ±5%. It handles motor ratings up to 75 hp at 480 V or 55 kW at 400 V. The unit is engineered for 10 operating cycles/hour, and supports overload currents of 300% Ie for 5 seconds.

Featuring relay output R1A/R1C NO and 24 V DC control voltage, this model includes built-in protection mechanisms: phase failure, thermal trip, bypass fault, and control voltage monitoring. The device is DIN-rail mountable and optimized for vertical ±30° installation, making it flexible across control panel configurations.

With dimensions of 197 mm (H) × 81 mm (W) × 180 mm (D) and a net weight of 2.3 kg, this unit is rated IP20 and operates efficiently up to 4000 m altitude (with derating). Power loss during startup is 703 W, with static consumption at just 3 W. Features like Boost and Deceleration Ramp enhance motor startup and shutdown performance.

The Schneider Altivar Soft Starter ATS130N2C11LT is ideal for industrial motors driving large compressors, water pumps, agitators, and HVAC systems. With high starting torque and soft acceleration, it protects mechanical components and reduces inrush currents, making it suitable for long-term use in manufacturing, utilities, and infrastructure.

Industrial engineers trust the ATS130 105A model for its rugged reliability and safety certifications. Whether for a new installation or retrofit, it aligns with IEC 60721-3-3 standards and supports PLC-level discrete input compatibility.

Request a Quote for Schneider ATS130N2C11LT today. At IndMALL, we deliver verified leads and competitive pricing to help your projects succeed faster than sourcing through general distributors.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.