+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

REL-MR-230AC/21HC: 2961422 -

Technical Specifications of REL-MR-230AC/21HC 2961422:

Phoenix Contact REL-MR-230AC/21HC 2961422
Product TypeSingle relay
Mechanical service life1x 107 cycles
Nominal input voltage UN230 V AC
Input voltage range179.4 V AC ... 356.5 V AC

REL-MR-230AC/21HC, 2961422 Technical Specifications:

SpecificationValue
Product typeSingle relay
Mechanical service life1x 107 cycles
Insulation-
Overvoltage categoryIII
Pollution degree3
Service life electricalsee diagram
Maximum power dissipation for nominal condition0.4 W
Test voltage (Winding/contact)5 kV AC (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)-
Rated insulation voltage-
Rated surge voltage-
Nominal input voltage UN230 V AC
Input voltage range179.4 V AC ... 356.5 V AC
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN3 mA (50 Hz)
Typical response time-
Coil voltage-
Status display-
Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage12 V (at 10 mA)
Limiting continuous current16 A
Maximum inrush current25 A (20 ms)
Min. switching current10 mA (at 12 V)
Interrupting rating (ohmic load) max.384 W (at 24 V DC)
Connection methodPlug / solder connection
Width12.7 mm
Height29 mm
Depth15.7 mm
Degree of protectionRT II
Degree of protection (Installation location)-
Ambient temperature (operation)-40 Β°C ... 85 Β°C
Ambient temperature (storage/transport)-40 Β°C ... 85 Β°C
Standards/regulationsIEC 60664
Mounting type-
Mounting positionany
Mains frequency50/60 Hz
Typical release time range2 ms ... 9 ms (depending on phase relation)
Coil resistance32500 Ξ© Β±15 % (at 20 Β°C)
Switching capacity2 A (at 24 V, DC13)
Motor load according to UL 5081/2 HP, 120 V AC (N/O contact)
Input power dissipation for UN-
3-phase motor load-
Product family-
Relay type-
Test voltage ()-
Degree of protection (Relay)-
Inrush current, minimum-
Non-operate voltage-
Safe operate voltage-
Test voltage (N/O contact / N/O contact)-
Call us for REL-MR-230AC/21HC part no: 2961422 at the best rates. Technical Attributes of REL-MR-230AC/21HC, 2961422 are mechanical service life of 1x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 230 V AC, with an input voltage range of 179.4 V AC ... 356.5 V AC. The typical input current at UN is 3 mA (50 Hz) with a response time of 3 ms ... 12 ms (depending on phase relation). The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 12 V (at 10 mA). It has a limiting continuous current of 16 A, with a maximum inrush current of 25 A (20 ms), and a minimum switching current of 10 mA (at 12 V). The interrupting rating for ohmic loads is 384 W (at 24 V DC). The connection method is via a Plug / solder connection, with a degree of protection rated at RT II. The sensor operates reliably in ambient temperatures ranging from -40 Β°C ... 85 Β°C. Unlock Exclusive Pricing with a Quote for your requirement of . Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.