+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

PTU 4-TWIN BU - 3211860 - Phoenix Hybrid Terminal Block

PTU 4-TWIN BU 3211860 Phoenix Hybrid Terminal Block

BrandPhoenix Contact
Product typeTerminal Block
ProductPTU 4-TWIN BU

PTU 4-TWIN BU , 3211860, Phoenix Hybrid Terminal Block Technical Specifications

SpecificationValue
Product typeHybrid terminal block
Number of connections3
Number of rows1
Potentials1
Overvoltage categoryIII
Degree of pollution3
Rated surge voltage8 kV
Maximum power dissipation for nominal condition1.02 W
Type of additional hybrid connectionUT 4
Number of connections per level3
Nominal cross section4 mmΒ²
Screw threadM3
Tightening torque0.6 ... 0.8 Nm
Stripping length10 mm ... 12 mm
Internal cylindrical gageA4
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.5 mmΒ² ... 6 mmΒ²
Cross section AWG26 ... 10 (converted acc. to IEC)
Conductor cross section flexible0.14 mmΒ² ... 6 mmΒ²
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mmΒ² ... 4 mmΒ²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mmΒ² ... 4 mmΒ²
Nominal current32 A
Maximum load current38 A (The maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal voltage800 V
Width6.2 mm
End cover width2.2 mm
Height69.3 mm
Depth on NS 35/7,542.8 mm
Depth on NS 35/1550.3 mm
Colorblue (RAL 5015)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 Β°C
Test voltage setpoint-
Short-time withstand current 2.5 mmΒ²-
Open side panelYes
DIN rail/fixing support-
Test force setpoint-
Rotation speed-
Revolutions-
Conductor cross section/weight-
Frequency-
ASD level-
Acceleration-
Test duration per axis-
Test directions-
Pulse shape-
Shock duration-
Number of shocks per direction-
Ambient temperature (operation)-60 Β°C ... 110 Β°C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 Β°C ... 60 Β°C (for a short time, not exceeding 24 h, -60 Β°C to +70 Β°C)
Ambient temperature (assembly)-5 Β°C ... 70 Β°C
Ambient temperature (actuation)-5 Β°C ... 70 Β°C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %
Mounting typeNS 35/7,5