Procurement managers rarely finalize PHOENIX-CONTACT-PSR-M-B3-SDI8-SDO4-DO4-PI without reviewing SMPS Phoenix, Phoenixcontact Phoenix Contact Industrial Ethernet Switches and Phoenixcontact Phoenix Contact Psr M Em5 1 Ttl2 Pi, ensuring that the chosen component meets budget, compliance, and delivery conditions.
Phoenix Contact PSR-M-B3-SDI8-SDO4-DO4-PI - 1300897 - Safety device
Technical Specifications of Safety device PSR-M-B3-SDI8-SDO4-DO4-PI 1300897

| Brand | Phoenix Contact |
| Product Type | Configurable Safety Module |
| Product | PSR-M-B3-SDI8-SDO4-DO4-PI |
Phoenix Contact Safety device PSR-M-B3-SDI8-SDO4-DO4-PI, 1300897 Technical Specifications
| Specification | Value |
|---|---|
| Product type | Safety device |
| Application | Emergency stop |
| Safety Integrity Level (SIL) | 2 (1channel wiring) |
| Control | 1 and 2 channel |
| Protection class | III |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Response time | see user manual |
| Restart time | min. 5 s (Boot time) |
| Maximum power dissipation for nominal condition | 9.85 W (with max. permissible load) |
| Nominal operating mode | 100% operating factor |
| Interfaces | DIN rail TBUS for connection to the master module, not supplied as standard |
| Rated surge voltage/insulation | See section รขยยInsulation coordinationรขยย |
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 24 V DC 20 % / +20 % (external fuse, typically 4 A) |
| Rated control supply current IS | 120 mA (RMS typ. inactive for all outputs) |
| Power consumption at US | typ. 2.88 W (Outputs inactive) |
| Inrush current | max. 600 mA (รยt < 25 ms) |
| Filter time | 250 ms (Test pulse rate > 1 s) |
| Protective circuit | Serial protection against polarity reversal |
| Description of the input | configurable (as signal output or reset input) |
| Number of inputs | 4 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC (for safe Off) |
| Input voltage range "1" signal | 11 V DC ... 28.8 V DC |
| Input current range "0" signal | < 2 mA |
| Cable length | max. 100 m |
| Max. permissible overall conductor resistance | 1 kรยฉ (Input and reset circuit at US) |
| Current consumption | typ. 12 mA (typ. with US) |
| Output description | nonsafetyrelated, configurable (as signal output or reset input) |
| Number of outputs | 4 (digital, PNP) |
| Short-circuit protection | Yes (selflimitation at 1.1 A) |
| Leakage current | max. 4.5 mA (in the Low state) |
| Max. capacitive load | max. 470 nF |
| Max. inductive load | max. 2.4 mH |
| Limiting continuous current | 100 mA (per channel) |
| Nominal output voltage | 24 V DC (Supply via A1) |
| Nominal output voltage range | 18.6 V DC ... 28.2 V DC (including all tolerances, including residual ripple US 0.7 V) |
| Switching frequency | max. 1/4 x tCycle [Hz] |
| Output voltage when switched off | max. 0.1 V |
| Test pulses | รขยยค 1 ms (Test pulse duration) |
| Discharging circuit | Yes, internal |
| Output voltage range | 18.2 V DC ... 27.8 V DC (US 1 V) |
| Voltage | 24 V DC (via A1) |
| Maximum inrush current | 1.1 A (รยt = 3 s at Us) |
| pluggable | yes |
| Connection method | USB 2.0 type C |
| Conductor cross section rigid | 0.2 mmรยฒ ... 2.5 mmรยฒ |
| Conductor cross section flexible | 0.2 mmรยฒ ... 2.5 mmรยฒ |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 10 mm |
| Status display | 1 x LED (green), 1 x LED (orange), 1 x LED (blue) |
| Operating voltage display | 1 x LED (green) |
| Error indication | 2 x LED (red) |
| Width | 45.2 mm |
| Height | 112.58 mm |
| Depth | 113.6 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | Polyamide PA nonreinforced |
| Performance level (PL) | e (2channel wiring) |
| Safety Integrity Level (SIL).1 | 3 (2channel wiring) |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | 20 รยฐC ... 55 รยฐC (observe derating) |
| Ambient temperature (storage/transport) | 30 รยฐC ... 85 รยฐC |
| Maximum altitude | รขยยค 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 95 % (noncondensing) |
| Max. permissible relative humidity (operation) | 95 % (noncondensing) |
| Shock | 10g for รยt = 16 ms (continuous shock, 1000 shocks in each space direction) |
| Vibration (operation) | 10 Hz ... 150 Hz, amplitude 0.15 mm, 2g |
| Identification | CEcompliant |
| Mounting type | DIN rail mounting |
| Assembly note | Observe derating |
| Mounting position | vertical or horizontal |
| Protection | typ. 4 A (A1) |
| Output voltage | max. 0.3 V (in the Low state) |
| Communication protocol | PROFINET |
| Number of connections | 1 |
| Transmission speed | 100 Mbps (Full duplex) |