Omron Timers — Analog, Digital & Multifunction Timers
Omron Timers perform time-based control functions within industrial automation systems using defined timing principles that regulate sequence, delay, interval, or cyclic operations. These devices support mechanical-relay or solid-state output structures, consistent panel-mounted or DIN-track installation formats, standardized input signal handling, and mode-selection mechanisms that vary by timer architecture while maintaining predictable behaviour under defined operating conditions.
The Omron Timers, manufactured by Omron, apply category-wide attributes such as universal timing modes, selector-based configuration elements, relay or transistor switching outputs, and front-mounted control interfaces referenced through the Omron product range. Structural characteristics include panel-enclosed housings, terminal-based wiring interfaces, actuation indicators, and logic blocks that govern time progression and output activation. Functional frameworks incorporate input gating, reset handling, output signalling, and compatibility with industrial control circuits. An Omron timer is defined as a time-governed control technology structured as a panel-integrated module classified under discrete timing and sequencing components and interfaced through mechanical or electronic output connections.
Omron H5CC Digital Timer
- Voltage Options: 100-240 VAC, 12-48 VDC/24 VAC, 24-240 VDC/24-240 VAC.
- Mounting: Flush, surface, DIN track options.
- Connections: Screw terminals, 11-pin or 8-pin socket.
- Display: 6-digit, 7-segment LCD; Time Ranges: 0.001 s to 999999 h.
- Modes: Elapsed time, remaining time; Inputs: Signal, Reset, Gate.
- Outputs: Multiple modes, contact and transistor options.
- Temperature Range:- 10 °C to 55°C; Protection: IP66 for panel surface.
Omron H3CR-A Timers
- Operating Modes: Multiple, including ON-delay, Flicker OFF/ON start, Signal ON/OFF-delay, Interval, One-shot.
- Pin Types: 11-pin and 8-pin models.
- Input Type: No-voltage and voltage input options.
- Output Type: Relay output (DPDT) for most models, transistor output (NPN/PNP universal) for some.
- Mounting Method: DIN track, surface, and flush mounting.
- Rated Operating Voltage: Options include 100 to 240 VAC, 24 to 48 VAC, 12 to 48 VDC.
Omron H3CR-F Solid-state Timer
- Operating Modes: Flicker OFF start, Flicker ON start.
- Pin Types: 11-pin and 8-pin models.
- Mounting Method: DIN track, surface, and flush mounting.
- Rated Operating Voltage: AC-15: 250 VAC, 3 A; AC-13: 250 VAC, 5 A; DC-13: 30 VDC, 1.5 A.
- Rated Insulation Voltage: 250 V; Time Ranges: Multiple, from 0.05 s to 300 h.
- Power Supply Voltage Options: 100 to 240 VAC 50/60 Hz/100 to 125 VDC, 24 to 48 VAC 50/60 Hz/12 to 48 VDC.
- Control Outputs: Contact output: 5 A at 250 VAC/30 VDC, resistive load.
Omron H3CA Timer
- Time Ranges: Adjustable from 0.1 s to 9,990 hrs with thumbwheel switch modules.
- Rated Supply Voltage: 24 to 240 VAC (50/60 Hz), 12 to 240 VDC.
- Operating Voltage Range: 85% to 110% of rated supply voltage.
- Power Consumption: Varies by model, up to approx. 10 VA/1.5 W.
- Control Outputs: 3 A at 250 VAC, resistive load; Accuracy of Operating Time: ±0.3% ±0.05 s.
- Reset Time: Depending on the model, 0.1 s to 0.5 s max.
- Insulation Resistance: 100 MΩ min. (at 500 VDC); Dielectric Strength: 2,000 VAC for 1 min.
Omron H3Y Timer
- Time Ranges: Adjustable from 0.04 s to 60 min, with various settings.
- Rated Supply Voltage: 100 to 230 VAC (50/60 Hz), 12 to 125 VDC.
- Operating Voltage Range: 85% to 110% of rated supply voltage.
- Power Consumption: Varies by voltage, up to 1.8 VA (AC) and 1.3 W (DC).
- Control Outputs: 5 A at 250 VAC (H3Y-2), 3 A at 250 VAC (H3Y-4), resistive load.
- Accuracy of Operating Time: ±1% FS max; Reset Time: 0.1 s max.
- Insulation Resistance: 100 MΩ min. (at 500 VDC); Dielectric Strength: 2,000 VAC for 1 min.
Omron H3YN Solid State Timer
- Time Ranges: selectable, 0.1 s to 10 min or 0.1 min to 10 h.
- Rated Supply Voltage: 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 100 to 110, 125 VDC.
- Operating Modes: ON-delay, interval, flicker OFF start, flicker ON start.
- Power Consumption: Varies by voltage, up to 2.2 VA (AC) and 1.6 W (DC).
- Control Outputs: DPDT: 5 A at 250 VAC; 4PDT: 3 A at 250 VAC.
- Accuracy of Operating Time: ±1% FS max; Reset Time: 0.1 s max.
- Insulation Resistance: 100 MΩ min. (at 500 VDC); Dielectric Strength: 2,000 VAC for 1 min.
Omron H5CX Timer
- Body Depth: Reduced for compact control panels.
- Display: Large characters, red/green/orange options.
- Operation: Simplified with Up/Down Keys.
- Safety: Isolated power supply and input circuits.
- Set Value Limit: Prevents operational errors.
- Output Counter: Monitors output activation frequency.
- Front Panel: Optional colors available.
- Input: Universal NPN/PNP compatibility.
Omron H3DT-A Solid-state Timer
- Operation: Single mode with power ON delay.
- Low Power Consumption: Reduces DC power supply load in control panels.
- Wiring: Push-In Plus terminal blocks for easy, tool-free wiring.
- Reliability: No need for retightening, ensuring secure connections.
- Ease of Use: Simple wire insertion, similar to an earphone jack.
Omron H5CZ Digital Timer
- Readability: Character height of 10 mm for clear visibility.
- Operation: Simplified with Up/Down Keys for each digit on 4-digit models.
- Safety and Reliability: Isolated power supply and input circuits for enhanced safety.
- Set Value Limit: Allows setting an upper limit to prevent operational errors.
- Output Counter: Counts the number of times the output turns ON, useful for service life management.
- Modes: 15 selectable modes, including a stopwatch mode.
Omron H5F Time Switch
- Voltage: 100-240 VAC (50/60 Hz).
- Power Consumption: Approx. 2.4 VA.
- Control Output: SPST-NO, 15 A at 250 VAC, 10 A at 24 VDC.
- Connections: Screw terminals (M3.5); Accuracy: ±0.01% ±0.05 s max.
- Insulation Resistance: 100 MΩ min; Dielectric Strength: 2,000 VAC for 1 min.
- Temperature Range: Operating -10°C to 55°C, Storage -25°C to 65°C.
Omron H3DT-H Solid-state Timer
- Voltage: 100-240 VAC (50/60 Hz).
- Power Consumption: Approx. 2.4 VA.
- Control Output: SPST-NO, 15 A at 250 VAC, 10 A at 24 VDC.
- Connections: Screw terminals (M3.5); Accuracy: ±0.01% ±0.05 s max.
- Insulation Resistance: 100 MΩ min; Dielectric Strength: 2,000 VAC for 1 min.
- Temperature Range: Operating -10°C to 55°C, Storage -25°C to 65°C.
Omron H5S Time Switch
- Voltage: 100-240 VAC (50/60 Hz), 24 VDC.
- Power Consumption: Approx. 2.9 VA (VAC), 0.8 W (VDC).
- Outputs: SPST-NO × 2 or 4 circuits.
- Load Capacity: 15 A at 250 VAC (resistive), 10 A at 250 VAC (inductive).
- Temperature Range: Operating -10 to 55°C, Storage -25 to 65°C.
- Accuracy: ±0.01% ±0.05 s max
- Insulation Resistance: 100 MΩ min; Dielectric Strength: 2,950 VAC for 1 min.
Omron H3RN Solid-state Timer
- Time Ranges: 0.1 s to 10 min/h.
- Voltage: 24 VAC, 12/24 VDC.
- Modes: ON-delay, interval, flicker start.
- Power Consumption: Up to 0.8 VA (VAC), 0.5 W (VDC).
- Output: 3 A at 250 VAC; Accuracy: ±1% FS max.
- Reset Time: Up to 0.5 s; Temperature Range: -10°C to 55°C.
- Insulation Resistance: 100 MΩ min; Dielectric Strength: 2,000 VAC.
Omron H3DK Timer
- Time Ranges: Adjustable from 0.1 s to 1,200 h across various settings.
- Power Supply Voltage: Options include 24 to 240 VAC/DC, 50/60 Hz, and 12 VDC.
- Power Consumption: Up to 4.5 VA (240 VAC) and 0.6 W (12 VDC).
- Control Output: 5 A at 250 VAC with resistive load, 5 A at 30 VDC with resistive load.
- Accuracy of Operating Time: ±1% of FS max.
- Insulation Resistance: 100 MΩ min. at 500 VDC.
- Dielectric Strength: 2,000 VAC for 1 min.
Omron H3CR-H Solid-state Timer
- Operating Methods: Various, including time-limit reset.
- Pin Types: 8-pin, 11-pin; Output: Relay (DPDT, SPDT).
- Mounting: DIN track, surface, flush.
- Voltage: 100-240 VAC/VDC, 48 VDC, 100-125 VDC.
- Time Ranges: 0.05 s to 12 s.
- Power Consumption: Up to 0.35 VA.
- Control Output: 5 A at 250 VAC/30 VDC.
The Omron timer range includes dependable solutions such as Omron H3FA Solid-state Timers, suitable for electronic timing applications requiring durability and precision. General-purpose timing needs are addressed by models like the Omron H3Y-4 Timer, while advanced digital control and clear display requirements are supported by the Omron H5AN Timer and Omron H5CN Timer. These timers offer multiple operating modes, wide voltage compatibility, and clear status indication, making them suitable for diverse industrial environments. By connecting buyers with Omron products available through established dealers and distributors, IndMALL Automation helps industries identify reliable timing solutions aligned with their operational requirements.
Frequently Asked Questions
What is Omron timer?
An Omron timer is a device produced by the Omron Corporation. It’s designed to measure and control time intervals for various applications. Used widely in industrial and automation settings, Omron timers ensure precision and reliability for tasks requiring timed operations or delays.
what is the function of timer in omron?
An Omron timer is an electronic tool. It manages and controls time intervals for tasks. This helps in automating processes in industries and homes.
How do you Set an Omron Timer?
To set an Omron timer, you usually follow these steps:
- Turn the power on to the timer.
- Use the mode or select button to choose the desired function.
- Adjust the time settings using the up or down buttons.
- Confirm or save the settings as directed.
However, specific steps can vary by model. Always check the user manual for the particular Omron timer you’re using.
How does a Omron H3CR timer work?
The Omron H3CR Timer is a versatile series of timers from the Omron Corporation, designed for industrial applications.
Mode Selection: The H3CR offers multiple modes, such as on-delay, off-delay, and interval. The user selects the desired mode based on the operation.
Time Setting: Using the front panel, users can set the time range (from seconds to hours) and adjust the desired timing within that range.
Signal Input: When the timer receives an input signal (like from a switch or another device), it starts its timing operation based on the selected mode.
Output: After the set time elapses, the H3CR activates or deactivates its output relay, controlling the connected device or process accordingly.
Reset: Many operations allow for manual or automatic reset, preparing the timer for its next cycle.
Always consult the specific H3CR manual for precise operation details and safety guidelines.