In sourcing discussions, MY4N-D2-DC24 is often placed next to Omron SMPS 24V 10A, My2N Gs Dc24 and Phoenix Slim Relay so procurement teams can align budgets and technical requirements effectively.
Omron MY4N-D2 DC24 Relay
The Omron MY4N-D2 DC24 Relay delivers reliable switching performance with a Closed type (cover) protective housing, Plug-in terminal structure compatible with a Socket for secure mounting. It provides a 4PDT contact form with a Single contact method and uses Au clad + Ag alloy contacts to ensure long electrical life. Supporting a max contact current of AC: 3 A DC: 3 A loads. Built with a 662 Ξ© coil resistance, it ensures dependable response with an 80% max. operate voltage and 10 % min. release voltage. Supporting 250 VAC 125 VDC maximum contact voltage. Manufactured by Omron, listed under Omron Relay solutions, this model belongs to theMY Series.

| Brand | Omron |
| Product | Relay |
| Model Number | MY4N-D2 DC24 |
Omron MY4N-D2 DC24 Relay - Technical Specifications
| Specification | Value |
|---|---|
| Terminal Structure | Plug-in terminal |
| Degree Of Protection | Closed type (cover) |
| Coil Resistance | 662 Ξ© |
| Operate Voltage Set Voltage | 80% max. |
| Release Voltage Reset Voltage | 10 % min. |
| Contact Rated Load | 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosΟ = 0.4)) 24 VDC 3 A (Resistive load) 24 VDC 1.5 A (Inductive load (L/R = 7 ms)) |
| Max Contact Voltage | 250 VAC 125 VDC |
| Max Contact Current | AC: 3 A DC: 3 A |
| Maximum Switching Power | 660 VA (Resistive load) 176 VA (Inductive load (cosΟ = 0.4)) 72 W (Resistive load) 36 W (Inductive load (L/R = 7 ms)) |
| Contact Method | Single |
| Contact Form | 4PDT |
| Mounting Method | Socket |
| Operating Indicator | LED |
| Coil Ratings | 24 VDC 36.3 mA |
| Coil Maximum Voltage | 110 % (23 β) |
| Contact Material | Au clad + Ag alloy |
| Power Consumption | Approx. 0.9 W |
| Coil Surge Killer | Diode |
| Contact Resistance | 50 mΞ© max. (Voltage drop method with 5 VDC 1 A) |
| Operating Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Reset Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Maximum Operating Frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
| Ambient Temperature Operating | -55 to 60 β (with no freezing or condensation) |
| Ambient Humidity Operating | 5 to 85% |
| Weight | Approx. 35 g |