If youβre not fully sure about MY4N-AC220-240, taking a closer look at Omron SMPS 24V 10A, My2N Gs Dc24 and Phoenix Slim Relay often helps compare reliability, cost, and availability.
Omron MY4N AC220/240 Relay
The Omron MY4N AC220/240 Relay delivers dependable multi-circuit switching with a closed-type housing, plug-in terminal structure, and a 220/240 VAC coil rating designed for precise control applications. It features a 4PDT contact configuration with a single contact method, supporting 3 A AC/DC maximum contact current and 250 VAC / 125 VDC maximum contact voltage. Built with a 18790 Ξ© coil resistance, LED operating indicator, fast 20 ms operation/reset time, and durable Au clad + Ag alloy contacts, it ensures stable performance. Capable of high-frequency mechanical operation, it withstands harsh environments from β55 to 60Β°C, ensuring long-life reliability in industrial control panels. Manufactured by Omron and listed under Omron Relay solutions, this model is listed under the Omron MY Series.

| Brand | Omron |
| Product | Relay |
| Model Number | MY4N AC220/240 |
Omron MY4N AC220/240 Relay - Technical Specifications
| Specification | Value |
|---|---|
| Terminal Structure | Plug-in terminal |
| Degree Of Protection | Closed type (cover) |
| Coil Resistance | 18790 Ξ© |
| Max Contact Voltage | 250 VAC 125 VDC |
| Max Contact Current | AC: 3 A DC: 3 A |
| Contact Method | Single |
| Mounting Method | socket |
| Operating Indicator | LED |
| Contacts Configuration | 4PDT |
| Coil Ratings | 200 VAC 50 Hz 4.8 mA 200 VAC 60 Hz 4.2 mA 220 VAC 50 Hz 5.3 mA 220 VAC 60 Hz 4.6 mA |
| Coil Maximum Voltage | 110% (23 β) |
| Coil Power Consumption | Approx. 0.9 to 1.3 VA 60 Hz |
| Contact Material | Au clad + Ag alloy |
| Contact Resistance | 50 mΞ© max. (Voltage drop method with 5 VDC 1 A) |
| Operating Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Reset Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Maximum Operating Frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
| Ambient Temperature Operating | -55 to 60 β (with no freezing or condensation) |
| Ambient Humidity Operating | 5 to 85% |