If youβre not fully sure about MKS2PIN-AC240, taking a closer look at Omron Photoelectric Sensor, My2N Gs Dc24 and Phoenix Slim Relay often helps compare reliability, cost, and availability.
Omron MKS2PIN AC240 Relay
The Omron MKS2PIN AC240 Relay delivers reliable switching performance with a Closed type (cover) protective housing, Plug-in terminal structure compatible with a Socket for secure mounting. It provides a DPDT contact form with a Single contact method and uses AgSnIn contacts to ensure long electrical life. Supporting a max contact current of AC: 10 A DC: 10 A loads. Built with a 4480 Ξ© coil resistance, it ensures dependable response with an 80% max. operate voltage and 25% min. (50 Hz) 30% min. (60 Hz) release voltage. Supporting 250 VAC 250 VDC maximum contact voltage. Manufactured by Omron, listed under Omron Relay solutions, this model belongs to theMK-S Series.

| Brand | Omron |
| Product Type | Relay |
| Model Number | MKS2PIN AC240 |
Omron MKS2PIN AC240 Relay - Technical Specifications
| Specification | Value |
|---|---|
| Terminal structure | Plug-in terminal |
| Degree of protection | Closed type (cover) |
| Coil resistance | 4480 Ξ© |
| Operate voltage (Set voltage) | 80% max. |
| Release voltage (Reset voltage) | 25% min. (50 Hz) 30% min. (60 Hz) |
| Max. contact voltage | 250 VAC 250 VDC |
| Max. Contact Current | AC: 10 A DC: 10 A |
| Contact method | Single |
| Contact form | DPDT |
| Contact resistance | 100 mΞ© max. (Voltage drop method with 5 VDC 1 A) |
| Operating time | 20 ms max. (With rated operating power applied, 23 β, not including contact bounce) |
| Reset time | 20 ms max. (With rated operating power applied, 23 β, not including contact bounce) |
| Maximum operating frequency | Mechanical: 18000 time/h Rated load: 1800 time/h |
| Ambient temperature (Operating) | -25 to 60 β |
| Ambient humidity (Operating) | 5 to 85% RH |
| Mounting method | Socket |
| Operating indicator | LED/Mechanical indicator |
| Coil ratings | 240 VAC 50 Hz 11.0 mA 240 VAC 60 Hz 9.6 mA |
| Coil Maximum voltage | 110 % |
| Contact material | AgSnIn |
| Power consumption | Approx. 2.7 VA 50 Hz/Approx. 2.3 VA 60 Hz |
| Insulation resistance | Between coil and contacts: 100 MΞ© min. (at 500 VDC) Between contacts of different polarity: 100 MΞ© min. (at 500 VDC) Between contacts of the same polarity: 100 MΞ© min. (at 500 VDC) |
| Coil Contact rated load | 250 VAC 10 A (NO contact: Resistive load) 250 VAC 5 A (NC contact: Resistive load) 250 VAC 7 A (Inductive load (cosΟ = 0.4)) 30 VDC 10 A (NO contact: Resistive load) 30 VDC 5 A (NC contact: Resistive load) |
| Contact Maximum switching power | 2500 VA (NO contact: Resistive load) 1250 VA (NC contact: Resistive load) 300 W (NO contact: Resistive load) 150 W (NC contact: Resistive load) |
| Weight | Approx. 90 g |