DTE20P: Delta 4 Channels of Platinum RTD Input

Technical Specifications of Delta 4 Channels of Platinum RTD Input DTE20P:

SpecValue
Chaannel Output0P: 4-channel PT
Power InputDC 24V, isolated switching power supply
Voltage Range90% ~ 110% rated voltage
Control MethodPID, PID programmable, manual, ON/OFF

Delta 4 Channels of Platinum RTD Input DTE20P Technical Specifications:

SpecificationValue
Channel / Output0P: 4-channel PT
Power inputDC 24V, isolated switching power supply
Voltage range90% ~ 110% rated voltage
Control methodPID, PID programmable, manual, ON/OFF
Power consumptionMax. 10W + 3W × number of DTC2000 controllers connected in parallel (Max. 7)
Sampling cycleThermocouple or platinum resistance: 1.0 second/all input
Alarm modes12 alarm modes available
Input sensorThermocouple: K, J, T, E, N, R, S, B, L, U, TXK Input sensor Platinum resistance: Pt100, JPt100, Cu50
Output accessories (optional)Relay output: SPST, Max. AC 250V load, 3A resistive load Voltage pulse output: DC 24V, Max. 40mA current output Current output: DC 4 ~ 20mA output (resistive load < 500); for OUT1 and OUT2 only Analog voltage output: 0 ~ 10V (resistive load > 1,000); for OUT1 and OUT2 only
Output functionsControl output, alarm output or proportional output (proportional output is only applicable in the model with linear voltage and current output for OUT1, OUT2)
CommunicationRS-485 digital communication; supports baud rate 2,400bps ~ 115,200bps
Communication protocolSupports Modbus ASCII/RTU
Vibration Resistance10 ~ 55Hz 10m/s2 3 axes 10mins
Shock ResistanceMax. 300m/s2 3 axes 6 directions, 3 times each
Ambient Temperature0°C ~ +50°C
Storage Temperature-20°C ~ +65°C
Operation altitude< 2,000m
Ambient humidity35% to 85% RH (non-condensing)
Pollution degree2
IndMALL Dealing in Delta 4 Channels of Platinum RTD Input, DTE20P at the best rates. Operational Specifications for DTE20P are 0P: 4-channel PT, DC 24V, isolated switching power supply , PID, PID programmable, manual, ON/OFF, 90% ~ 110% rated voltage. And It Delivers Max. 10W + 3W × number of DTC2000 controllers connected in parallel (Max. 7), Thermocouple or platinum resistance: 1.0 second/all input, 12 alarm modes available. Unlock Exclusive Pricing with a Quote for your requirement of Delta 4 Channels of Platinum RTD Input. Experience the advantage of our pricing and support against other Traders.