DTE2CT | Delta 4 Channels of Current Transformer Sensors
+91 79955 44066 sales@indmall.in

DTE2CT: Delta 4 Channels of Current Transformer Sensors

Technical Specifications of Delta 4 Channels of Current Transformer Sensors DTE2CT:

SpecValue
Chaannel OutputCT: 4 channels of current transformer sensors
Power InputDC 24V, isolated switching power supply
Voltage Range90% ~ 110% rated voltage
Control MethodPID, PID programmable, manual, ON/OFF

Delta 4 Channels of Current Transformer Sensors DTE2CT Technical Specifications:

SpecificationValue
Channel / OutputCT: 4 channels of current transformer sensors
Power inputDC 24V, isolated switching power supply
Voltage range90% ~ 110% rated voltage
Control methodPID, PID programmable, manual, ON/OFF
Power consumptionMax. 10W + 3W × number of DTC2000 controllers connected in parallel (Max. 7)
Sampling cycleThermocouple or platinum resistance: 1.0 second/all input
Alarm modes12 alarm modes available
Input sensorThermocouple: K, J, T, E, N, R, S, B, L, U, TXK Input sensor Platinum resistance: Pt100, JPt100, Cu50
Output accessories (optional)Relay output: SPST, Max. AC 250V load, 3A resistive load Voltage pulse output: DC 24V, Max. 40mA current output Current output: DC 4 ~ 20mA output (resistive load < 500); for OUT1 and OUT2 only Analog voltage output: 0 ~ 10V (resistive load > 1,000); for OUT1 and OUT2 only
Output functionsControl output, alarm output or proportional output (proportional output is only applicable in the model with linear voltage and current output for OUT1, OUT2)
CommunicationRS-485 digital communication; supports baud rate 2,400bps ~ 115,200bps
Communication protocolSupports Modbus ASCII/RTU
Vibration Resistance10 ~ 55Hz 10m/s2 3 axes 10mins
Shock ResistanceMax. 300m/s2 3 axes 6 directions, 3 times each
Ambient Temperature0°C ~ +50°C
Storage Temperature-20°C ~ +65°C
Operation altitude< 2,000m
Ambient humidity35% to 85% RH (non-condensing)
Pollution degree2
IndMALL Automation Offers Delta 4 Channels of Current Transformer Sensors, DTE2CT with exclusive offers. Component Specifications of DTE2CT features PID, PID programmable, manual, ON/OFF, 90% ~ 110% rated voltage, DC 24V, isolated switching power supply , CT: 4 channels of current transformer sensors. It rounds off its features with 12 alarm modes available, Thermocouple or platinum resistance: 1.0 second/all input, Max. 10W + 3W × number of DTC2000 controllers connected in parallel (Max. 7). Don't Miss Out on a Quote for your requirement of Delta 4 Channels of Current Transformer Sensors. Our competitive edge: better pricing and support than other Suppliers.