DRP048V240W1BA - Delta 5A 48V DIN Rail Power Supply
Technical Specifications of Delta DRP048V240W1BA 5A 48V DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRP048V240W1BA |
Delta 5A 48V DIN Rail Power Supply DRP048V240W1BA Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 5A |
| Output Voltage | 48V |
| Output Voltage Adjustment Range | 48-56Vdc |
| Output Power | 240W |
| Line Regulation | < 0.5% (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 85-264Vac input, 0-100% load) |
| PARD | < 200mVpp |
| Start-up Time | < 1,000ms @ nominal input (100% load) |
| Hold-up Time | > 20ms @ 115Vac, > 115ms @ 230Vac |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 2% @ 85-264Vac input, 10-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz) |
| Start-up with Capacitive Loads | 10,000µF Max |
| Rise Time | < 200ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 2.50A @ 115Vac, < 1.30A @ 230Vac |
| Efficiency at 100% load | > 90.0% @ 115Vac, > 92.0% @ 230Vac |
| Inrush Current | < 35A @ 115Vac, @ 230Vac |
| Power Factor at 100% load | > 0.96 @ 115Vac, > 0.90 @ 230Vac |
| Leakage Current | < 1mA @ 240Vac |
| Power Dissipation | 0% load: < 6.5W @ 115Vac, < 5.5W @ 230Vac 100% load: < 25W @ 115Vac, < 19W @ 230Vac |
| Case Chassis / Cover | Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 300V/15A) |
| Output Terminal | 4 Pins (Rated 300V/15A) |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input / Output: AWG 18-12 |
| Unit Weight | 0.96 kg (2.12 lb) |
| Operating Temperature | -25°C to +80°C (Cold Start at -40°C) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical: > 50°C de-rate power by 2.5% / °C Horizontal: > 40°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 times per direction, 2 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 2,500 Meters (8,200 ft.) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
Talk to Our Engineer for Delta 5A 48V DIN Rail Power Supply DRP048V240W1BA with exclusive offers. Core System Specifications of DRP048V240W1BA are 5A Output Current, 48V Output Voltage, 240W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of < 2.50A @ 115Vac, < 1.30A @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 300V/15A) and 4 Pins (Rated 300V/15A) for secure connections. Designed for extreme environments, it Operating Temperature from -25°C to +80°C (Cold Start at -40°C) and has a storage temperature of -40°C to +85°C. Don't Miss Out on a Quote for your requirement of 5A 48V DIN Rail Power Supply. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.