DRP024V120W1BA - Delta 5A 24V DIN Rail Power Supply
Technical Specifications of Delta DRP024V120W1BA 5A 24V DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRP024V120W1BA |
Delta 5A 24V DIN Rail Power Supply DRP024V120W1BA Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 5A |
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28Vdc |
| Output Power | 120W |
| Line Regulation | < 0.5% (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 85-264Vac input, 0-100% load) |
| PARD | < 150mVpp |
| Start-up Time | < 1000ms @ nominal input (100% load) |
| Hold-up Time | > 20ms @ 115Vac, > 115ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 85-264Vac input, 10-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
| Start-up with Capacitive Loads | 10,000µF Max |
| Rise Time | < 50ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 2.20A @ 115Vac, < 1.10A @ 230Vac |
| Efficiency at 100% load | > 89.0% @ 115Vac, > 90.0% @ 230Vac |
| Inrush Current | < 35A @ 115Vac & 230Vac |
| Power Factor at 100% load | - |
| Leakage Current | < 1mA @ 240Vac |
| Power Dissipation | 0% load: < 0.3W @ 115Vac & < 0.5W @ 230Vac 100% load: < 7.0W @ 115Vac & 230Vac |
| Case Chassis / Cover | Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 300V/15A) |
| Output Terminal | 4 Pins (Rated 300V/15A) |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input / Output: AWG 20-14 |
| Unit Weight | 0.72 kg (1.59 lb) |
| Operating Temperature | -25°C to +80°C (Cold Start at -40°C) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical / Horizontal: > 50°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 time per direction, 2 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 2,000 Meters (6,560 ft) |
| Pollution Degree | 2 |
| Bump Test (Operating) | - |
| Over Voltage Category | III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
Send Your Inquiry for Delta 5A 24V DIN Rail Power Supply DRP024V120W1BA with cost-effective solutions. Essential Technical Specs of DRP024V120W1BA are 5A Output Current, 24V Output Voltage, 120W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of < 2.20A @ 115Vac, < 1.10A @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 300V/15A) and 4 Pins (Rated 300V/15A) for secure connections. Designed for extreme environments, it Operating Temperature from -25°C to +80°C (Cold Start at -40°C) and has a storage temperature of -40°C to +85°C. Capture the Best Deal with a Quote for your requirement of 5A 24V DIN Rail Power Supply. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.