+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

DRL-24V240W1AA - Delta 10A 24V DIN Rail Power Supply

Technical Specifications of Delta DRL-24V240W1AA 10A 24V DIN Rail Power Supply

BrandDelta
Product TypeSMPS
ProductDRL-24V240W1AA

Delta 10A 24V DIN Rail Power Supply DRL-24V240W1AA Technical Specifications:

SpecificationValue
Output Current10A
Output Voltage24V
Output Power240W
Output Voltage Adjustment Range22-28Vdc
Line Regulation< 0.5% (@ 85-264Vac, 100% load)
Load Regulation< 1.0% (0-100% load)@ > -10°C to +70°C < 1.5% (0-100% load) @ ≤ -10°C to -20°C
PARD< 120mVpp @ -10°C to +70°C < 240mVpp @ -20°C to -10°C
Start-up Time1000ms typ.@ 115Vac & 230Vac (100% load)
Hold-up Time10ms typ.@ 115Vac (100% load) 16ms typ.@ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% (2400mVpp) @ 85-264Vac input, 0-50% load, 50-100% load (Slew Rate: 0.1A/μs)
Start-up with Capacitive Loads8,000µF Max
Rise Time100ms typ. @ nominal input (100% load)
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
DC Input Voltage Range120-375Vdc
Input Current2.8A typ.@115Vac, 1.4A typ.@ 230Vac
Efficiency at 100% load88.0%typ.@115Vac, 90.0% typ.@ 230Vac
Inrush Current20A typ.@115Vac, 40A typ.@ 230Vac
Leakage Current< 1mA @ 264Vac
Case Chassis / CoverSGCC / Aluminium
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Unit Weight0.80 kg (1.76 lb)
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6m/s² (2G peak); displacement of 0.35mm; 10 min per cycle, 60 min for X direction
Shock Test (Operating)IEC 60068-2-27, 27, Half Sine Wave: 10G for duration of 11ms; 1 time for X direction
Operating Temperature-20°C to +70°C
Storage Temperature-40°C to +85°C
Power De-rating> 40°C de-rate power by 1.67% / °C @ 115Vac (90-229Vac) > 50°C de-rate power by 2.5% / °C @ 230Vac (230-264Vac) < 100Vac de-rate power by 1% / Vac
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, 27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz; 2.09Grms; 20 min per axis for all X, Y, Z directions
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Power Dissipation0% load: 4.62W @ 115Vac, 2.14W @ 230Vac 100% load: 31.53W @ 115Vac, 25.44W @ 230Vac
Input Terminal3 Pins (Rated 600V/35A)
Output Terminal6 Pins (Rated 300V/28A)
Signal Terminal6 Pins (Rated 300V/28A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 16-12 Output: AWG 16-12 Signal: AWG 16-12
Mail Us for your needs in Delta 10A 24V DIN Rail Power Supply DRL-24V240W1AA with budget-friendly prices. The Main Technical Parameters of DRL-24V240W1AA include 10A Output Current, 24V Output Voltage, 240W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of 2.8A typ.@115Vac, 1.4A typ.@ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 600V/35A) and 6 Pins (Rated 300V/28A) for secure connections. Designed for extreme environments, it Operating Temperature from -20°C to +70°C and has a storage temperature of -40°C to +85°C. Customize Your Experience with a Quote for your requirement of 10A 24V DIN Rail Power Supply. Experience the difference with our competitive pricing and superior support over other Suppliers.