Omron E2E-X7D1-M1J-T Proximity Sensor
Omron E2E-X7D1-M1J-T is a cylindrical M18 shielded inductive proximity sensor with a 7 mm sensing distance and a 0 to 5.6 mm setting distance. It uses a DC 2-wire NO output through an oil-resistant PVC M12 standard prewired connector and operates from 12 to 24 VDC. Ferrous metal is the specified target, paired with an iron 18 × 18 × 1 mm standard sensing object. Response frequency is 0.5 kHz, while control output is rated from 3 to 100 mA with a 50 mA diagnostic output. The E2E-X7D1-M1J-T belongs to M18 shielded proximity sensors from Omron automation sensor solutions.

| Brand | Omron |
| Product | Proximity Sensors |
| Model Number | E2E-X7D1-M1J-T |
Omron E2E-X7D1-M1J-T Proximity Sensor - Technical Specifications
| Specification | Value |
|---|---|
| Sensor | Inductive |
| Housing Shape | Cylindrical |
| Size | M18 |
| Mounting type | Shielded |
| Sensing Distance | 7 mm |
| Setting Distance | 0 to 5.6 mm |
| Output configuration | DC 2-wire |
| Operation Mode | NO |
| Connection Method | M12 Standard Prewired Connector |
| Cable specifications | PVC (oil-resistant) |
| Wire color / pin arrangement | (3, 4): (+V, 0 V) |
| Detectable Object | Ferrous metal |
| Standard Sensing Object | Iron, 18 × 18 × 1 mm |
| Response Frequency | 0.5 kHz |
| Power Supply Voltage | 12 to 24 VDC |
| Protection Circuit | Surge suppressor, Load short-circuit protection (for control and diagnostic output) |
| Ambient Temperature Range | Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation) |
| Degree of Protection | IEC 60529 IP67 |
| Control Output | 3 to 100 mA, Diagnostic output: 50 mA |
| Indicators | Operation indicator (red) and setting indicator (green) |
| Materials | Nickel-plated brass, Polybutylene terephthalat (PBT), Nickel-plated brass, Zinc-plated iron, Vinyl chloride (PVC). |
| Weight | Approx. 70 g |
The Omron E2E-X7D1-M1J-T Proximity Sensor uses a cylindrical M18 shielded inductive sensing body with a 7 mm sensing distance and a 0 to 5.6 mm setting distance. It provides DC 2-wire NO operation through an M12 standard prewired connector with an oil-resistant PVC cable and operates from 12 to 24 VDC. Ferrous metal is the specified detectable object, paired with an iron 18 × 18 × 1 mm standard sensing object. Response frequency is 0.5 kHz. Control output is rated from 3 to 100 mA, while diagnostic output is rated 50 mA. Red and green indicators show operation and setting status, with surge suppression and load short-circuit protection specified.
Operating conditions for the E2E-X7D1-M1J-T cover -25 to 70°C, while storage extends from -40 to 85°C without icing or condensation. IEC 60529 IP67 is specified for environmental protection. Nickel-plated brass, PBT, zinc-plated iron, and PVC are listed among the construction materials. The shielded M18 format combines a 7 mm sensing distance with DC 2-wire NO switching and an M12 prewired connection. Its oil-resistant PVC cable specification supports industrial installations where cable durability is relevant. Ferrous metal remains the stated sensing target. For a compact small-diameter E2E model with 0.8 mm sensing distance and DC 3-wire PNP output, see E2E-C03SR8-CJ-B1 0.3M.