Omron MKS2PIN AC240 Relay
The Omron MKS2PIN AC240 Relay delivers reliable switching performance with a Closed type (cover) protective housing, Plug-in terminal structure compatible with a Socket for secure mounting. It provides a DPDT contact form with a Single contact method and uses AgSnIn contacts to ensure long electrical life. Supporting a max contact current of AC: 10 A DC: 10 A loads. Built with a 4480 Ξ© coil resistance, it ensures dependable response with an 80% max. operate voltage and 25% min. (50 Hz) 30% min. (60 Hz) release voltage. Supporting 250 VAC 250 VDC maximum contact voltage. Manufactured by Omron, listed under Omron Relay solutions, this model belongs to theMK-S Series.
| Brand | Omron |
| Product | Relay |
| Model Number | MKS2PIN AC240 |
Omron MKS2PIN AC240 Relay - Technical Specifications
| Specification | Value |
|---|
| Terminal Structure | Plug-in terminal |
| Degree Of Protection | Closed type (cover) |
| Coil Resistance | 4480 Ξ© |
| Operate Voltage Set Voltage | 80% max. |
| Release Voltage Reset Voltage | 25% min. (50 Hz) 30% min. (60 Hz) |
| Max Contact Voltage | 250 VAC 250 VDC |
| Max Contact Current | AC: 10 A DC: 10 A |
| Contact Method | Single |
| Contact Form | DPDT |
| Mounting Method | Socket |
| Operating Indicator | LED/Mechanical indicator |
| Coil Ratings | 240 VAC 50 Hz 11.0 mA 240 VAC 60 Hz 9.6 mA |
| Coil Maximum Voltage | 110% |
| Contact Material | AgSnIn |
| Power Consumption | Approx. 2.7 VA 50 Hz/Approx. 2.3 VA 60 Hz |
| Contact Resistance | 100 mΞ© max. (Voltage drop method with 5 VDC 1 A) |
| Operating Time | 20 ms max. (With rated operating power applied, 23 β, not including contact bounce) |
| Reset Time | 20 ms max. (With rated operating power applied, 23 β, not including contact bounce) |
| Maximum Operating Frequency | Mechanical: 18000 time/h Rated load: 1800 time/h |
| Ambient Temperature Operating | -25 to 60 β |
| Ambient Humidity Operating | 5 to 85% RH |
| Insulation Resistance | Between coil and contacts: 100 MΞ© min. (at 500 VDC) Between contacts of different polarity: 100 MΞ© min. (at 500 VDC) Between contacts of the same polarity: 100 MΞ© min. (at 500 VDC) |
| Coil Contact Rated Load | 250 VAC 10 A (NO contact: Resistive load) 250 VAC 5 A (NC contact: Resistive load) 250 VAC 7 A (Inductive load (cosΟ = 0.4)) 30 VDC 10 A (NO contact: Resistive load) 30 VDC 5 A (NC contact: Resistive load) |
| Contact Maximum Switching Power | 2500 VA (NO contact: Resistive load) 1250 VA (NC contact: Resistive load) 300 W (NO contact: Resistive load) 150 W (NC contact: Resistive load) |
| Weight | Approx. 90 g |