Omron G3PW-A260EC-C-FLK Solid-state Relay
Omron G3PW-A260EC-C-FLK is a single-phase G3PW power controller specified with a 60 A rated operational current and constant-current control. It operates across an 85 to 264 V range with a 100 to 240 V rated operational voltage and a 1 to 5 V control input. The supplied data includes push-in terminals, heater burnout detection, Serial RS-485 communication, a 1600 A²s permissible I²t rating, and a 14 kW heater load capacity. Its stated operating-temperature range is -15°C to 55°C. The G3PW-A260EC-C-FLK power-control unit belongs to the G3PW series within the Solid state power-control family from Omron switching and control products.

| Brand | Omron |
| Product | Solid State Relay |
| Model Number | G3PW-A260EC-C-FLK |
Omron G3PW-A260EC-C-FLK Solid-state Relay - Technical Specifications
| Specification | Value |
|---|---|
| Application | Power control |
| Number Of Phases | 1 |
| Terminal Type | Push-in |
| Features | Constant current |
| Rated Operational Voltage Ac | 100-240 V |
| Operating Voltage Range Ac | 85-264 V |
| Rated Operation Current Ie At Ac 1 | 60 A |
| Permissible I T Value | 1600 A²s |
| Applicable Heater Capacity Ac1 Resistive Load | 14 kW |
| Supply Voltage Dc | 1-5 V |
| Maximum Operating Temperature | 55 °C |
| Minimum Operating Temperature | -15 °C |
| Functions | Heater burnout detection |
| Communication Port S | Serial RS-485 |
The Omron G3PW-A260EC-C-FLK Solid State Relay is the 60 A single-phase power controller in this supplied G3PW batch. Its rated operational voltage is 100 to 240 V, while its operating range is 85 to 264 V. The source lists a 1 to 5 V control input, push-in terminals, and constant-current control. Heater burnout detection and Serial RS-485 communication are also populated for this model. Permissible I²t is rated at 1600 A²s, and the applicable heater load capacity is 14 kW. Operating temperature is specified from -15°C to 55°C. These values establish its current, voltage, control, protection, communication, terminal, and heater-capacity characteristics within the supplied G3PW data.
The G3PW-A260EC-C-FLK shares the same 1600 A²s permissible I²t value, 100 to 240 V rated voltage, 85 to 264 V operating span, 1 to 5 V control input, constant-current control, heater burnout detection, and Serial RS-485 fields with the 45 A A245EC-C-FLK row. The principal supplied differences are the 60 A rated operational current, the 14 kW heater-capacity value, and the push-in terminal listing. Its stated ambient range remains -15°C to 55°C. For the lower-current model in the same EC-C-FLK group with an 11 kW heater-capacity figure, see G3PW-A245EC-C-FLK.