+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

ELX3314-0090 - Beckhoff EtherCAT Terminal Analog Input

Technical Specifications of Beckhoff EtherCAT Terminal Analog Input ELX3314-0090:

BrandBeckhoff
Product TypeEtherCAT Terminal Analog Input
ProductELX3314-0090

ELX3314-0090 Beckhoff EtherCAT Terminal Analog Input Technical Specifications

SpecificationValue
Number of inputs4 (differential)
Measurement error/uncertaintytyp. รขย‰ยฅ 10 kรŽยฉ (differential)
Input filter limit frequencytyp. 1 kHz; depending on sensor length, conversion time, sensor type
Measurement error/uncertainty 2< ร‚ยฑ0.3% (relative to full scale value)
Housing - Design formcompact terminal housing with signal LEDs
Housing - Materialpolycarbonate, blue
Housing - Dimensions (W x H x D)12ร‚ mm x 100ร‚ mm x 68 mm
Housing - Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Housing - Side by side mounting by means ofdouble slot and key connection
Housing - Markinglabeling of the BZxxxx series
Housing - Wiringsolid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Housing - Connection cross-sections*: 0.08....2.5mmยฒ,st*: 0.08...2.5mmยฒ,f*: 0.14....1.5 mmยฒ
Housing - Connection cross-section AWGs*: AWG28...14,st*: AWG28...14,f*: AWG26...16
Housing - Stripping length8โ€ฆ9 mm
Conversion time10รขย€ยฆ5000 ms (adjustable, default: 310 ms)
Current consumption E-bustyp. 70 mA
Special featureslimit value monitoring, digital filter and characteristic curve linearization integrated, TwinSAFE SC
Weightapprox. 60 g
Operating temperature-25....+60ยฐC
Storage temperature-40....+85ยฐC
Relative humidity95%, no condensation
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP20/see documentation
Approvals/markingsCE, UL, ATEX, IECEx, cFMus
Current consumption power contactstyp. 10 mA
Ex markingATEX:ร‚ ร‚ II 3(1)G Ex ec [ia Ga] IIC T4 Gcร‚ ร‚ II (1)D [Ex ia Da] IIICร‚ ร‚ I (M1) [Ex ia Ma] IIECEx:ร‚ ร‚ Ex ec [ia Ga] IIC T4 Gcร‚ ร‚ [Ex ia Da] IIICร‚ ร‚ [Ex ia Ma] IcFMus:ร‚ ร‚ AIS Class I, II, III, Division 1, Groups A thru Gร‚ ร‚ Class I, Division 2, Groups A, B, C, Dร‚ Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gcร‚ ร‚ [AEx ia Da] IIIC T4
Sensor typesthermocouples type K, J, L, E, T, N, U, B, R, S, C (default: type K)
Connection method2-wire
Measuring rangedepending on sensor type, default type K: -200รขย€ยฆ+1350ร‚ยฐC, voltage measurement: ร‚ยฑ30รขย€ยฆร‚ยฑ100ร‚ mV, for further types and details see documentation

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.