Procurement managers rarely finalize ELX3314-0090 without reviewing Beckhoff El9410, El9550 Beckhoff and Beckhoff El2809, ensuring that the chosen component meets budget, compliance, and delivery conditions.
ELX3314-0090 - Beckhoff EtherCAT Terminal Analog Input
Technical Specifications of Beckhoff EtherCAT Terminal Analog Input ELX3314-0090:

| Brand | Beckhoff |
| Product Type | EtherCAT Terminal Analog Input |
| Product | ELX3314-0090 |
ELX3314-0090 Beckhoff EtherCAT Terminal Analog Input Technical Specifications
| Specification | Value |
|---|---|
| Number of inputs | 4 (differential) |
| Measurement error/uncertainty | typ. รขยยฅ 10 kรยฉ (differential) |
| Input filter limit frequency | typ. 1 kHz; depending on sensor length, conversion time, sensor type |
| Measurement error/uncertainty 2 | < รยฑ0.3% (relative to full scale value) |
| Housing - Design form | compact terminal housing with signal LEDs |
| Housing - Material | polycarbonate, blue |
| Housing - Dimensions (W x H x D) | 12ร mm x 100ร mm x 68 mm |
| Housing - Installation | on 35 mm DIN rail, conforming to EN 60715 with lock |
| Housing - Side by side mounting by means of | double slot and key connection |
| Housing - Marking | labeling of the BZxxxx series |
| Housing - Wiring | solid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver |
| Housing - Connection cross-section | s*: 0.08....2.5mmยฒ,st*: 0.08...2.5mmยฒ,f*: 0.14....1.5 mmยฒ |
| Housing - Connection cross-section AWG | s*: AWG28...14,st*: AWG28...14,f*: AWG26...16 |
| Housing - Stripping length | 8โฆ9 mm |
| Conversion time | 10รขยยฆ5000 ms (adjustable, default: 310 ms) |
| Current consumption E-bus | typ. 70 mA |
| Special features | limit value monitoring, digital filter and characteristic curve linearization integrated, TwinSAFE SC |
| Weight | approx. 60 g |
| Operating temperature | -25....+60ยฐC |
| Storage temperature | -40....+85ยฐC |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/see documentation |
| Approvals/markings | CE, UL, ATEX, IECEx, cFMus |
| Current consumption power contacts | typ. 10 mA |
| Ex marking | ATEX:ร ร II 3(1)G Ex ec [ia Ga] IIC T4 Gcร ร II (1)D [Ex ia Da] IIICร ร I (M1) [Ex ia Ma] IIECEx:ร ร Ex ec [ia Ga] IIC T4 Gcร ร [Ex ia Da] IIICร ร [Ex ia Ma] IcFMus:ร ร AIS Class I, II, III, Division 1, Groups A thru Gร ร Class I, Division 2, Groups A, B, C, Dร Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gcร ร [AEx ia Da] IIIC T4 |
| Sensor types | thermocouples type K, J, L, E, T, N, U, B, R, S, C (default: type K) |
| Connection method | 2-wire |
| Measuring range | depending on sensor type, default type K: -200รขยยฆ+1350รยฐC, voltage measurement: รยฑ30รขยยฆรยฑ100ร mV, for further types and details see documentation |