Before procurement teams confirm TELEMECANIQUESENSORS-XCSDMC79010EX, they typically review Telemecanique Limit Switch, Telemecanique Telemecaniquesensors Xcspa791 and Telemecanique Safety Interlock Switches Accessories to double-check performance ratings, stock availability, and supplier credibility carefully.
Telemecaniquesensors XCSDMC79010EX
Technical Specifications of Telemecaniquesensors Coded Magnetic Switches XCSDMC79010EX:

| [Ue] rated operational voltage | 24 V DC |
| [Ie] rated operational current | 100.0000 MILLIAMPERE |
| Switching capacity in mA | 0.1...100 mA |
| Insulation resistance | 1000 MOhm |
Telemecanique Coded Magnetic Switches XCSDMC79010EX Technical Specifications
| Specification | Value |
|---|---|
| Range of product | Telemecanique Safety switches XCS |
| Product or component type | Coded magnetic switch |
| Device short name | XCSDMC |
| Material | Plastic |
| Contacts type and composition | 2 NC |
| Contact operation | Staggered |
| Electrical connection | Pre-cabled |
| Cable composition | 4 x 0.25 mm² |
| Design | Rectangular, compact |
| Size | 51 x 16 x 7 mm |
| Approach directions | 3 directions |
| [Ue] rated operational voltage | 24 V DC |
| [Ie] rated operational current | 100.0000 MILLIAMPERE |
| Contacts material | Rhodium |
| Switching capacity in mA | 0.1...100 mA |
| Insulation resistance | 1000 MOhm |
| Switching frequency | 150 Hz |
| Safety level | Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508 |
| Safety reliability data | B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear |
| Protective treatment | TH |
| Vibration resistance | 10 gn (f= 10-150 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 30 gn for 11 ms conforming to IEC 60068-2-27 |
| Sensitivity to magnetic fields | 0.3000 MILLITESLA |
| Electrical shock protection class | Class II conforming to IEC 60536 |
| IP degree of protection | IP66 conforming to IEC 60529, IP67 conforming to IEC 60529 |
| Enclosure material | Thermoplastic PBT |
| Cable material | PVC |
| Dust zone | Zone 0 - 1 - 2/20 - 21 - 22 |
| Product certifications | INERIS 07ATEX0036 |
| Standards | EN 60079-18 |
| Directives | 2014/34/EU - ATEX directive |