A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1,
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1,
Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1,
Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
Actuator force for extraction
20.0000 NEWTON
Operating rate
10 cyc/mn for maximum durability
Body material
Zamak
Head material
Zamak
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1,
can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1,
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Protective treatment
TC
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to EN/IEC 60536
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1