During technical comparisons, TELEMECANIQUESENSORS-XCKMR54D1H29SCJ appears alongside Schmersal Limit Switch, Telemecanique Limit Switch and Telemecanique Telemecaniquesensors Xckj390541H29Ex so engineers assess signal types, ingress protection, and ambient tolerances accurately.
Telemecanique XCKMR54D1H29SCJ: Standard Limit Switches Classic range
Technical Specifications of Telemecanique Standard Limit Switches Classic range XCKMR54D1H29SCJ:

| Product or component type | Limit switch |
| Cable entry | 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7-13 mm |
| Contacts type and composition | 2 x (2 NC) |
| Contact operation | Slow-break, staggered |
Telemecanique Standard Limit Switches Classic range XCKMR54D1H29SCJ Technical Specifications
| Specification | Value |
|---|---|
| Range of product | OsiSense XC |
| Series name | Special format |
| Product or component type | Limit switch |
| Device short name | XCKMR |
| Body type | Fixed |
| Head type | Rotary head |
| Material | Metal |
| Body material | Zamak |
| Fixing mode | By the body |
| Movement of operating head | Rotary |
| Type of operator | Stay put crossed rods lever metal square rod 6 mm, L = 200 mm |
| Type of approach | Lateral approach, 2 directions |
| Cable entry | 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7-13 mm |
| Contacts type and composition | 2 x (2 NC) |
| Contact operation | Slow-break, staggered |
| Switch actuation | By any moving part |
| Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm² |
| Contacts insulation form | Zb |
| Positive opening | With |
| Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A, Q150, DC-13 (Ue = 125 V), Ie = 0.55 A conforming to EN/IEC 60947-5-1 appendix A |
| Resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
| Terminals description ISO n°1 | (11-12)NC |
| Shock resistance | 50 gn conforming to EN/IEC 60068-2-27 |
| Vibration resistance | 25 gn (f= 10-500 Hz) conforming to EN/IEC 60068-2-6 |
| IP degree of protection | IP66 conforming to EN/IEC 60529 |
| IK degree of protection | IK07 conforming to EN 50102 |
| Electrical shock protection class | Class I conforming to IEC 60536 |
| Protective treatment | TC |
| Standards | UL 508 |
| Product certifications | UL |
| Repeat accuracy | - |
| Product specific application | For hoisting and mechanical handling applications |
| Head material | Zamak |
| Contact block per direction [control circuit] | 1 per direction |
| Sensor design | - |
| Overvoltage category | - |
| Product compatibility | - |
| Contacts material | - |
| Environmental characteristic | - |
| Local display | - |