+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Sick RLY3-EMSS100 Safety Relay

RLY3-EMSS100 1085345 Sick 24V Safety Relay Technical Specifications

BrandSick
Product TypeSafety Relay
ProductRLY3-EMSS100

Sick RLY3-EMSS100 Safety Relay – Technical Specifications

SpecificationValue
Compatible sensor typesSafety sensors with potential-free outputs
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (ISO 13849-1)
Performance levelPL e (ISO 13849-1)
TM (mission time)20 years (ISO 13849-1)
Sensor monitoringDiscrepancy monitoring, Cross-circuit detection
Restart interlockβœ”
ResetAutomatic, Manual
External device monitoring (EDM)βœ”
Connection typeFront connector with spring terminals
Inputs2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM)
Outputs2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe)
Display elementsLEDs
Configuration methodHard wired
Supply voltage VS24 V DC (16.8 V ... 30 V)
Residual ripple≀ 2.4 V
Power consumption≀ 2.5 W (DC)
Input voltage HIGH24 V DC (11 V ... 30 V)
Input voltage LOW0 V DC (–3 V ... 5 V)
Input current4 mA ... 6 mA
Test pulse width-
Test pulse rate-
Response time10 ms
Type of outputN/O contacts, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage10 V AC ... 230 V AC, 10 V DC ... 230 V DC
Switching current10 mA ... 6 A
Total current12 A
Overvoltage categoryIII (EN 60664-1)
Rated impulse withstand voltage Uimp6 kV (EN 60664-1)
Output voltage HIGHβ‰₯ Vs – 3 V
Output voltage LOW≀ 3 V
Input current (NPN)≀ 15 mA
Output current (PNP)≀ 120 mA
Output voltageβ‰₯ Vs – 3 V
Test pulse interval40 ms
Dimensions (W x H x D)18 mm x 124.6 mm x 85.5 mm
Enclosure ratingIP20 (IEC 60529)
Ambient operating temperature–25 Β°C ... +55 Β°C
Storage temperature–25 Β°C ... +70 Β°C
Air humidity≀ 95 %, Non-condensing
Interference emissionAccording to IEC 61000-6-4
Interference resistanceAccording to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1
Weight130 g
Get A Quote for Sick 24V Safety Relay RLY3-EMSS100 part no: 1085345 at the best price. Here are the brief Technical Specifications of RLY3-EMSS100, 1085345 features Safety sensors with potential-free outputs and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features Discrepancy monitoring, Cross-circuit detection, Automatic, Manual reset. The relay has a Front connector with spring terminals, 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM). Outputs include 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) and LEDs for display elements and is configured through a Hard wired method. It supports 24 V DC (16.8 V ... 30 V) supply voltage, ≀ 2.4 V residual ripple, and ≀ 2.5 W (DC) power consumption. The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (–3 V ... 5 V), with an input current of 4 mA ... 6 mA with a response time of 10 ms. The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. Output voltage HIGH is β‰₯ Vs – 3 V, and output voltage LOW is ≀ 3 V. The input current (NPN) is ≀ 15 mA, and the output current (PNP) is ≀ 120 mA, with an output voltage of β‰₯ Vs – 3 V and a test pulse interval of 40 ms. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of –25 Β°C ... +55 Β°C and storage temperatures of –25 Β°C ... +70 Β°C, with air humidity of ≀ 95 %, Non-condensing. It's Time to get a Quote for your requirement of Sick 24V Safety Relay. We guarantee unmatched pricing and unparalleled support compared to other Distributors.