If you’re not fully sure about MZC2-1V7NS-SU0, taking a closer look at Sick Diffuse Sensor, Sick Photoelectric Sensor Gl and Sick Laser Sensor often helps compare reliability, cost, and availability.
MZC2-1V7NS-SU0: Sick MZC2 with Axial Cable Connection for Tight Spaces
Technical specifications of Sick MZC2 with Axial Cable Connection for Tight Spaces MZC2-1V7NS-SU0:

| Housing Length | 19.5 mm |
| Switching Output | NPN |
| Output Function | NO |
| Conenction Type | Cable, 3-wire, drag chain use, 2 m |
Sick MZC2 with Axial Cable Connection for Tight Spaces MZC2-1V7NS-SU0 Technical Specifications:
| Specification | Value |
|---|---|
| Cylinder Type | C-slot |
| Preferred Manufacturer Slot | SMC, Schunk, PHD, Bimba |
| Housing Length | 19.5 mm |
| Switching Output | NPN |
| Switching Frequency | 1,000 Hz |
| Output Function | NO |
| Electrical Wiring | DC 3-wire |
| Enclosure Rating | IP67 |
| Special Features | Completely embedded mounting in the slot, providing protection |
| Supply Voltage | 10 V DC ... 30 V DC |
| Power Consumption | 8 mA, without load |
| Voltage Drop | ≤ 2.5 V |
| Continuous Current Ia | ≤ 100 mA |
| Protection Class | III |
| Ex Area Category | - |
| Device Labeling | - |
| Response Sensitivity (Typ.) | ≤ 1.7 mT |
| Overrun Distance (Typ.) | 2 mm |
| Hysteresis (Typ.) | ≤ 0.4 mT |
| Reproducibility | ≤ 0.1 mT |
| Reverse Polarity Protection | Yes |
| Short-Circuit Protection | Yes |
| Status Indicator LED | Yes |
| Power-Up Pulse Protection | Yes |
| Ambient Operating Temperature | –25 °C ... +75 °C |
| Shock and Vibration Resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
| EMC | According to EN 60947-5-2 |
| Connection Type | Cable, 3-wire, drag chain use, 2 m |
| Conductor Cross Section | 0.09 mm² |
| Cable Diameter | Ø 1.9 mm |
| Bending Radius | With fixed installation = 12 x cable diameter |
| Material Housing / Plastic Cable PUR | Material |
| Housing | Plastic |
| Cable | PUR |
Obtain a Quote for Sick MZC2 with Axial Cable Connection for Tight Spaces MZC2-1V7NS-SU0 at economical prices. Specifications Overview for MZC2-1V7NS-SU0 reveals housing length of 19.5 mm, engineered for precise industrial automation. These sensors feature a NPN switching output with a switching frequency of up to 1,000 Hz, ensuring rapid response. The output function is (normally open) NO, utilizing a DC 3-wire electrical connection. With an IP67 enclosure rating, these sensors are protected against dust and water ingress. The supply voltage ranges from 10 V DC ... 30 V DC, consuming just 8 mA, without load. The voltage drop is ≤ 2.5 V, and the continuous current is rated at ≤ 100 mA. The typical response sensitivity is ≤ 1.7 mT, with an overrun distance of 2 mm, making it ideal for precision applications. The conductor cross-section is 0.09 mm², with a cable diameter of Ø 1.9 mm and an axial cable outlet. The housing is made of durable Plastic, while the cable is constructed from high-quality PUR. Take the First Step with a Quote for your requirement of Sick MZC2 with Axial Cable Connection for Tight Spaces. Our commitment to better pricing and exceptional support sets us apart from other Competitors.