MPA-863THTP0: Sick Universal Round Body Cylinder Position Sensors
Technical Specifications of Sick Universal Round Body Cylinder Position Sensors MPA-863THTP0:

| Measuring range | 863 mm |
| Output function | Analog, IO-Link |
| Electrical Wiring | DC 4-wire |
| Connection Type | Cable with M8 male connector, 4-pin, 0.3 m |
Sick Universal Round Body Cylinder Position Sensors MPA-863THTP0 Technical Specifications:
| Specification | Value |
|---|---|
| Cylinder type | Universal |
| Cylinder types with adapter | Round body cylinderTie rod cylinderT-slot cylindersFesto cylinders DSBCSMC cylinders CP96 |
| Measuring range | 863 mm |
| Housing length | 865 mm |
| Output function | Analog, IO-Link |
| Electrical wiring | DC 4-wire |
| Analog output (voltage) | 0 V ... 10 V |
| Analog output (current) | 4 mA ... 20 mA |
| Enclosure rating | IP65, IP67, IP68 |
| IO-Link functions | Standard functions |
| Teach-in control panel | Teaching in the measuring rangeSelecting the current/voltage output or IO-LinkResetting the measuring range to factory settings |
| IO-Link | Teaching in the measuring rangeResetting the measuring range |
| Supply voltage | 15 V DC ... 30 V DC |
| Power consumption | 35 mA, without load |
| Max. load resistance | ≤ 500 Ω Power Output, at 24 V |
| Min. load resistance | ≥ 2 kΩ |
| Protection class | III |
| Required magnetic field sensitivity, typ. | 2 mT ... 15 mT |
| Resolution, typ. | 0.03 % FSR (max. ≥ 0.06 mm) |
| Linearity error, typ. | 0.5 mm |
| Repeat accuracy, typ. | 0.06 % FSR (≥ 0.1 mm) |
| Sampling rate, typ. | 1.15 ms |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Status indicator LED | Yes |
| Teach-in | Yes |
| Ambient operating temperature | –20 °C ... +70 °C |
| Shock and vibration resistance | 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm |
| EMC | According to EN 60947-5-2 |
| Connection type | Cable with M8 male connector, 4-pin, 0.3 m |
| Deep-freeze property | Do not bend below 0 °C |
| Conductor cross section | 0.08 mm² |
| Cable diameter | Ø 2.6 mm |
| Bending radius | With fixed installation > 5 x cable diameter |
| Cable outlet | Axial |
| Housing | Metal, Aluminum, plastic |
| Cable | PUR |
| Communication interface | IO-Link V1.0.1 |
| Communication Interface detail | COM2 |
| Cycle time | 2.3 ms |
| Process data length | 16 Bit |
Talk to Our Engineer for Sick Universal Round Body Cylinder Position Sensors MPA-863THTP0 with exclusive offers. Core System Specifications of MPA-863THTP0 are measuring range of 863 mm and a housing length of 865 mm, featuring both Analog, IO-Link output functionality. It operates on a DC 4-wire electrical system and provides an analog voltage output of 0 V ... 10 V as well as a current output of 4 mA ... 20 mA , making it ideal for precise measurements. Rated IP65, IP67, IP68 , the sensor ensures reliable performance in tough industrial environments. The IO-Link provides Standard functions for seamless integration. The supply voltage ranges from 15 V DC ... 30 V DC, with a power consumption of 35 mA, without load. The connection type is a Cable with M8 male connector, 4-pin, 0.3 m, offering flexible connectivity. The housing is made of durable Metal, Aluminum, plastic while the cable material is PUR, ensuring long-term reliability in industrial applications. Don't Miss Out on a Quote for your requirement of Sick Universal Round Body Cylinder Position Sensors. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.