Sick Safety Light Curtains
Safety light curtains like the SICK C4000 Advanced Safety Light Curtain and SICK deTec Safety Light Curtain are used to protect operators by detecting entry into hazardous machine areas without physical contact. They are widely used in press machines, robotic cells, packaging lines, and automated systems. On IndMALL, you can explore these with Pan India supply.
SICK Safety Light Curtains such as miniTwin and C4000 Fusion offer high reliability and fast response for industrial safety. On IndMALL, connect with Verified Suppliers, Direct Connection, and Faster Response to find the right solution.
Sick Light Curtains: C4000 Advanced
The C4000 Standard and Advanced Safety Light Curtains from SICK feature:
- Resolution: 20 mm.
- Scanning Range: 1.5 m to 19 m.
- Protective Field Height: 300 mm to 1800 mm.
- Operating Temperature: 0 °C to +55 °C; Enclosure Rating: IP 65.
- Vibration Resistance: 5 g (10 Hz to 55 Hz).
- Shock Resistance: 10 g, 16 ms; Light Source: LED, 650 nm wavelength.
Sick Safety Light Curtains: C4000 Fusion
SICK C4000 Fusion safety light curtain offers:
- Non-contact position and speed recording.
- Measuring lengths up to 4 meters.
- High traversing speeds up to 10 m/s.
- Protective field height from 300 mm to 1800 mm.
- Scanning range of 1.5 m to 19 m.
- 20 mm resolution; IP 65 enclosure rating.
Sick M4000 Light Curtain
M4000 Advanced, M4000 Advanced A/P, and Multiple Light Beam Safety Devices from SICK offer the following main specifications:
- Operating Principle: Multiple light beam safety device.
- Muting Principle: Includes various muting configurations with two or four sensors.
- Configurable Functions: Restart interlock, beam coding, application diagnostic output (ADO), scanning range, external device monitoring (EDM), sender test.
- Scanning Range: Varies based on the model.
- Safety Features: Includes comprehensive safety measures and diagnostics.
Sick Light Curtain: deTec
- Resolution: 30 mm; Scanning Range: 15 m.
- Protective Field Height: 1,800 mm.
- System Connection: Male connector M12, 5-pin.
- Supply Voltage: 24 V DC (19.2 V to 28.8 V).
- Power Consumption: Typical 1.3 W (DC).
- Housing: Aluminum extruded profile; Enclosure Rating: IP65, IP67.
- Operating Temperature: –30 °C to +55 °C.
- Vibration Resistance: 5 g, 10 Hz to 55 Hz; Shock Resistance: 10 g, 16 ms.
Sick Light Barrier: miniTwin
- Resolution: 14 mm.
- Scanning Range: 0 m to 8 m; Protective Field Height: 600 mm.
- Response Time: ≤ 14 ms; Connection: Male connector M12, 5-pin.
- Supply Voltage: 24 V DC (19.2 V to 28.8 V).
- Power Consumption: ≤ 3 A.
- Housing: Aluminum alloy; Enclosure Rating: IP65.
- Operating Temperature: –20 °C to +55 °C.
- Vibration and Shock Resistance: 5 g (10 Hz to 55 Hz) and 10 g (16 ms).
Safety Light Curtain Sick: M4000 Area
M4000 Area 60/80 Multiple Light Beam Safety Device from SICK offers the following main specifications:
- Scanning Range: The scanning range of the M4000 Area 60/80 is detailed in the document.
- Configurable Functions: Includes restart interlock, beam coding, application diagnostic output (ADO), scanning range, external device monitoring (EDM), and sender test.
- Safety Features: Comprehensive safety measures and diagnostics are included.
- Applications: Suitable for access protection, hazardous area protection, and more.
Sick Detec4 Light Curtain
- Automatic calibration of protective field width.
- No blind zones for uninterrupted safety coverage.
- Alignment aid for easy setup.
- Various mounting options with QuickFix, FlexFix, and other brackets.
- Electrical connection via M12, 5-pin connector.
- Status indicators for operational monitoring.
Sick Safety Curtain: mac4
mac4 Safety Light Curtain from SICK offers:
- Type: Extension module.
- Resolution: 30 mm; Protective Field Height: 210 mm.
- Scanning Range: 0.4 m to 3.2 m.
- Response Time: 12 ms to 20 ms; Connection: Male connector M12, 4-pin.
- Supply Voltage: 24 V DC (21 V to 27 V); Power Consumption: 2 W (DC).
- Enclosure Rating: IP65; Operating Temperature: 0 °C to +50 °C.
- Vibration and Shock Resistance: 5 g (10 Hz to 55 Hz) and 10 g (16 ms).
Sick Safety Light Curtains
Suppliers
Sick Safety Light Curtains
Models
C4MT-01214ABB03BE0
Range: 0 to 5 m
Height: 120 mm
Response: ≤ 14 ms
Safety: SIL 3 / PL e
IP: IP65
C4MT-01214ABB03BB0
Range: 0 to 5 m
Height: 120 mm
Response: ≤ 14 ms
Safety: SIL 3 / PL e
IP: IP65
C4MT-01814ABB03BE0
Range: 0 to 5 m
Height: 180 mm
Response: ≤ 14 ms
Safety: SIL 3 / PL e
IP: IP65
C4MT-03014ABB03DE0
Range: 0 to 5 m
Height: 300 mm
Response: ≤ 14 ms
Safety: SIL 3 / PL e
IP: IP65
C4MT-04814ABB03DE0
Range: 0 to 5 m
Height: 480 mm
Response: ≤ 14 ms
Safety: SIL 3 / PL e
IP: IP65
C4MT-12014ABB03FE0
Range: 0 to 5 m
Height: 1200 mm
Response: ≤ 17 ms
Safety: SIL 3 / PL e
IP: IP65
Frequently Asked Questions
How to Set Up Sick Light Curtains?
After alignment, turn off the alignment laser, then test the machine to ensure the light curtain functions correctly. For flexible mounting, use Flex Fix brackets. Ensure the installation area is clear, and check cable lengths according to specifications.
How to Align Sick Light Curtains?
To align SICK light curtains, start by mounting the transmitter and receiver brackets at the same height. Make sure they’re level and straight. Rotate the transmitter cylinder toward the receiver. If using a model like deTec, activate the laser alignment aid. Adjust the transmitter until the laser hits the blue alignment LEDs on the receiver.
Continue rotating the receiver until four blue LEDs illuminate and the field LEDs turn green, indicating proper alignment. Turn off the alignment laser, then safely test the system to ensure accurate detection.
What is the Range of the Sick M4000?
The range of the SICK M4000 safety light curtain varies from 0.5 to 70 meters. It has two configurations: a low scanning range of 0.5 to 20 meters and an extended range of 9 to 70 meters. This versatile safety device is used for perimeter and access guarding in high-risk areas.
The M4000 offers modular features, allowing users to customize it to fit specific safety needs. It also has configurable functions, which can be set using the keys on the device. This makes it suitable for various industrial environments.
What is the Detection Capability of the Light Curtain?
A light curtain’s detection capability refers to its ability to sense objects within a protective field. It uses closely spaced infrared beams to detect intrusions. When any beam is interrupted, the curtain sends a stop signal to the guarded machine. This technology is crucial for safety in automated and industrial environments.
What is the Light Curtain Muting Concept?
The light curtain muting concept involves temporarily disabling the safety function. This allows authorized objects, like materials on a conveyor, to pass without stopping the process. Muting is controlled by sensors and logic, ensuring safety for humans while maintaining operational efficiency. It’s essential in automated material handling and manufacturing processes.
What is the Purpose of a Safety Light Curtain?
A safety light curtain is designed to protect personnel from injuries related to hazardous machinery. It uses infrared beams to create an invisible safety barrier. When this barrier is breached, the machinery automatically shuts down, preventing potential accidents.
If you require Sick Light Curtains or Sick Safety Light Curtains get a Call: at +91 79955 44066