Before procurement teams confirm ELECTRIC-TM241C40T, they typically review Siemens PLC, Magelis HMI Software and Schneider M241 40 Io Transistor Npn to double-check performance ratings, stock availability, and supplier credibility carefully.
Schneider TM241C40T Programmable Logic Controller
The TM241C40T is a high-performance PLC from Schneider Electric, part of the Modicon M241 range. Designed for efficient industrial automation, it supports 24 V DC input voltage and offers versatile transistor and relay outputs, making it ideal for complex automation systems.
| Brand | Schneider |
| Product Type | Programmable Logic Controller (PLC) |
| Product | TM241C40T |
Schneider TM241C40T Programmable Logic Controller – Technical Specifications
| Specification | Value |
|---|---|
| Model | TM241C40T |
| Manufacturer | Schneider Electric |
| Product Type | Programmable Logic Controller (PLC) |
| Series | Modicon TM241 |
| Power consumption in W | 32.6…40.4 W (with max number of I/O expansion module) |
| Output voltage limits | 30 V DC |
| Depth | 95 mm |
| Discrete input voltage type | DC |
| Maximum number of I/O expansion module | 7 (local I/O-Architecture)14 (remote I/O-Architecture) |
| Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232480 Mbit/s for bus length of 3 m for USB |
| Range of product | Modicon M241 |
| Width | 190 mm |
| Backup time | 2 years at 25 °C |
| Reset time | 10 ms automatic reset output12 s automatic reset fast output |
| Height | 90 mm |
| Discrete output type | Transistor |
| Discrete output current | 0.1 A for fast output (PTO mode) (Q0...Q3)0.5 A for transistor output (Q0...Q15) |
| Response time | <= 2 µs turn-on, I0...I7 terminal(s) for fast input<= 2 µs turn-off, I0...I7 terminal(s) for fast input<= 2 µs turn-on, Q0...Q3 terminal(s) for fast output<= 2 µs turn-off, Q0...Q3 terminal(s) for fast output50 µs turn-on, I0...I15 terminal(s) for input50 µs turn-off, I0...I15 terminal(s) for input<= 34 µs turn-on, Q0...Q15 terminal(s) for output<= 250 µs turn-off, Q0...Q15 terminal(s) for output |
| Discrete output number | 16 transistor 4 fast output |
| Discrete output logic | Positive logic (source) |
| Shock resistance | 15 gn for 11 ms |
| Protection type | Short-circuit protectionShort-circuit and overload protection with automatic resetReverse polarity protection for fast output |
| Supply voltage limits | 20.4…28.8 V |
| Discrete input number | 24, discrete input 8 fast input conforming to IEC 61131-2 Type 1 |
| Communication port protocol | Non isolated serial link: Modbus master/slave |
| Inrush current | 50 A |
| Electrical connection | removable screw terminal blockfor inputs and outputs (pitch 5.08 mm) removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm) |
| Net weight | 0.62 kg |
| Operating altitude | 0...2000 m |
| Discrete input voltage | 24 V |
| Ambient air temperature for storage | -25…70 °C |
| Storage altitude | 0…3000 m |
| Discrete input logic | Sink or source |
| Pollution Degree | 2 |
| Insulation | Between supply and internal logic at 500 V ACNon-insulated between supply and groundBetween input and internal logic at 500 V ACNon-insulated between inputsBetween fast input and internal logic at 500 V ACBetween output and internal logic at 500 V ACNon-insulated between outputsBetween fast output and internal logic at 500 V ACBetween output groups at 500 V AC |
The Schneider TM241C40T delivers reliable performance in industrial automation environments. It operates with a power consumption range of 32.6 to 40.4 W when connected to the maximum number of I/O expansion modules. The controller features output voltage limits of 30 V DC for transistor output and 125 V DC for relay output, ensuring compatibility with a wide range of devices.
With a compact 95 mm depth, it is easy to integrate into tight spaces, making it suitable for diverse automation setups. The TM241C40T supports a supply voltage range of 20.4 to 28.8 V and handles inrush currents up to 50 A. It operates effectively up to 2000 m altitude and supports storage at altitudes up to 3000 m.