+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

LP1K1210JD: Schneider TeSys K 12A Contactor 12VDC Coil

Technical Specifications of Schneider TeSys K 12A Contactor 12VDC Coil LP1K1210JD:

Power pole contact composition3 NO
Control Circuit TypeDC standard
Inrush power in W3 W 68 °F (20 °C))
Connection Terminalsscrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.002 in² (1.5 mm²)flexible with cable end

Schneider TeSys K 12A Contactor 12VDC Coil LP1K1210JD Technical Specifications:

SpecificationValue
RangeTeSys
Product or Component TypeContactor
Device short nameLP1K
Contactor applicationMotor controlResistive load
Utilisation categoryAC-3AC-3eAC-1AC-4
Poles description3P
Power pole contact composition3 NO
[Ue] rated operational voltagePower circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type [Uc]DC standard
Control circuit voltage12 V DC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 140 °F (60 °C)) for power circuit10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity144 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current115 A 122 °F (50 °C) - 1 s for power circuit105 A 122 °F (50 °C) - 5 s for power circuit100 A 122 °F (50 °C) - 10 s for power circuit75 A 122 °F (50 °C) - 30 s for power circuit55 A 122 °F (50 °C) - 1 min for power circuit50 A 122 °F (50 °C) - 3 min for power circuit25 A 122 °F (50 °C) - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit 600 V UL 508Power circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-5-1Signalling circuit 600 V UL 508Power circuit 600 V CSA C22.2 No 14Signalling circuit 600 V CSA C22.2 No 14
Inrush power in W3 W 68 °F (20 °C))
Hold-in power consumption in W3 W 68 °F (20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at <122 °F (50 °C))Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
Connections - terminalsscrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable endPower circuit screw clamp terminals 2 0.002 in² (1.5 mm²)flexible with cable end
Maximum operating rate3600 cyc/h
Mounting SupportRailPlate
Operating time30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening
Height2.3 in (58 mm)
Width1.8 in (45 mm)
Depth2.2 in (57 mm)
Net Weight0.496 lb(US) (0.225 kg)
IP degree of protectionIP2X
Ambient air temperature for operation-13…122 °F (-25…50 °C)
Ambient Air Temperature for Storage-58…176 °F (-50…80 °C)
Operating altitude6561.68 ft (2000 m) without derating
Get A Quote for Schneider TeSys K 12A Contactor 12VDC Coil LP1K1210JD at the best price. Here are the brief Technical Specifications of LP1K1210JD are Contactor Product or Component Type 3 NO power pole contact composition. This contactor operates with a rated operational voltage of up to Power circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz, ensuring flexibility in various industrial applications. The control circuit operates on a DC standard with a control voltage of 12 V DC, providing reliable control functionality. It has a rated impulse withstand voltage of 8 kV, conforming to industry standards for electrical safety. The compact design includes a height of 2.3 in (58 mm), a width of 1.8 in (45 mm), and a depth of 2.2 in (57 mm). It's Time to get a Quote for your requirement of Schneider TeSys K 12A Contactor 12VDC Coil. We guarantee unmatched pricing and unparalleled support compared to other Distributors.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.