Technical Specifications of Schneider 12A 3P TeSys K Contactor LP1K1210FD:

[Uc] control circuit voltage110 V DC
Auxiliary Contact Composition1 NO
Mounting SupportRailPlate
Inrush power in W3 W (at 20 °C)

Schneider 12A 3P TeSys K Contactor LP1K1210FD Technical Specifications:

SpecificationValue
Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
[Uc] control circuit voltage110 V DC
Minimum switching voltage17 V for signalling circuit
contactor applicationMotor controlResistive load
Width45 mm
Control circuit typeDC standard
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Depth57 mm
[Ie] rated operational current12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Auxiliary contacts typetype instantaneous 1 NO
poles description3P
Auxiliary contact composition1 NO
IP degree of protectionIP2X
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14
Operating altitude2000 m without derating
Ambient air temperature for operation-25…50 °C
Power pole contact composition3 NO
Hold-in power consumption in W3 W at 20 °C
Ambient air temperature for storage-50…80 °C
Utilisation categoryAC-3AC-3eAC-1AC-4
Insulation resistance> 10 MOhm for signalling circuit
Heat dissipation1.3 W
Hold-in power consumption in VA-
Net weight0.225 kg
Minimum switching current5 mA for signalling circuit
Mounting supportRailPlate
Operating time30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening
Rated breaking capacity110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Product or component typeContactor
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 20.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Maximum operating rate3600 cyc/h
RangeTeSys
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz
Height58 mm
Motor power kW3 kW at 220...230 V AC 50/60 Hz AC-35.5 kW at 380...415 V AC 50/60 Hz AC-35.5 kW at 440 V AC 50/60 Hz AC-34 kW at 690 V AC 50/60 Hz AC-33 kW at 220...230 V AC 50/60 Hz AC-3e5.5 kW at 380...415 V AC 50/60 Hz AC-3e5.5 kW at 440 V AC 50/60 Hz AC-3e4 kW at 690 V AC 50/60 Hz AC-3e3 kW at 220...230 V AC 50/60 Hz AC-45.5 kW at 380...415 V AC 50/60 Hz AC-45.5 kW at 440 V AC 50/60 Hz AC-4
Inrush power in W3 W (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
Electrical durability1.3 Mcycles 12 A AC-3 at Ue <= 440 V1.3 Mcycles 12 A AC-3e at Ue <= 440 V0.3 Mcycles 20 A AC-1 at Ue <= 690 V0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Device short nameLP1K
Send Your Inquiry for Schneider 12A 3P TeSys K Contactor LP1K1210FD with cost-effective solutions. Essential Technical Specs of LP1K1210FD are control circuit voltage [Uc] operates at 110 V DC, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. It is suitable for both motor Motor controlResistive load applications. The control circuit type is DC standard, and the auxiliary contacts are type instantaneous 1 NO configuration, providing reliable switching. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. The utilization categories include AC-3AC-3eAC-1AC-4, making it suitable for a wide range of applications. Product or component type Contactor. Capture the Best Deal with a Quote for your requirement of Schneider 12A 3P TeSys K Contactor. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.