In most procurement cycles, ELECTRIC-LP1K090085MD is considered with Schneider VFD, ABB Contactors and Schneider Altivar Machine Atv340, giving decision-makers confidence that they’ve chosen the most dependable component.
LP1K090085MD: Schneider 220V DC TeSys K Contactor
Technical Specifications of Schneider 220V DC TeSys K Contactor LP1K090085MD:

| [Uc] control circuit voltage | 220 V DC |
| Auxiliary Contact Composition | - |
| Mounting Support | Printed circuit boards |
| Inrush power in W | 3 W (at 20 °C) |
Schneider 220V DC TeSys K Contactor LP1K090085MD Technical Specifications:
| Specification | Value |
|---|---|
| Connections - terminals | Solder pins (external diameter: 0.035 mm) |
| [Uc] control circuit voltage | 220 V DC |
| Minimum switching voltage | - |
| contactor application | Resistive load |
| Width | 45 mm |
| Control circuit type | DC standard |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Depth | 57 mm |
| [Ie] rated operational current | 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
| Auxiliary contacts type | - |
| poles description | 4P |
| Auxiliary contact composition | - |
| IP degree of protection | IP2X |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V conforming to CSA C22.2 No 14 |
| Operating altitude | 2000 m without derating |
| Ambient air temperature for operation | -25…50 °C |
| Power pole contact composition | 2 NO + 2 NC |
| Hold-in power consumption in W | 3 W at 20 °C |
| Ambient air temperature for storage | -50…80 °C |
| Utilisation category | AC-1 |
| Insulation resistance | - |
| Heat dissipation | 1.3 W |
| Hold-in power consumption in VA | - |
| Net weight | 0.225 kg |
| Minimum switching current | - |
| Mounting support | Printed circuit boards |
| Operating time | 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening25...35 ms coil energisation and NC opening15 ms coil de-energisation and NC closing |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
| Product or component type | Contactor |
| Tightening torque | - |
| Maximum operating rate | 3600 cyc/h |
| Range | TeSys |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
| Height | 58 mm |
| Motor power kW | 4 kW at 690 V AC 50/60 Hz AC-4 |
| Inrush power in W | 3 W (at 20 °C) |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Electrical durability | 0.16 Mcycles 20 A AC-1 at Ue <= 690 V |
| Device short name | LP1K |
Talk to Our Engineer for Schneider 220V DC TeSys K Contactor LP1K090085MD with exclusive offers. Core System Specifications of LP1K090085MD are control circuit voltage [Uc] operates at 220 V DC, with a minimum switching voltage of -, ensuring responsive operation. It is suitable for both motor Resistive load applications. The control circuit type is DC standard, and the auxiliary contacts are - configuration, providing reliable switching. The sensor features a 4P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. The utilization categories include AC-1, making it suitable for a wide range of applications. Product or component type Contactor. Don't Miss Out on a Quote for your requirement of Schneider 220V DC TeSys K Contactor. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.