LP1K090085MD: Schneider 220V DC TeSys K Contactor

Technical Specifications of Schneider 220V DC TeSys K Contactor LP1K090085MD:

[Uc] control circuit voltage220 V DC
Auxiliary Contact Composition-
Mounting SupportPrinted circuit boards
Inrush power in W3 W (at 20 °C)

Schneider 220V DC TeSys K Contactor LP1K090085MD Technical Specifications:

SpecificationValue
Connections - terminalsSolder pins (external diameter: 0.035 mm)
[Uc] control circuit voltage220 V DC
Minimum switching voltage-
contactor applicationResistive load
Width45 mm
Control circuit typeDC standard
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Depth57 mm
[Ie] rated operational current20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Auxiliary contacts type-
poles description4P
Auxiliary contact composition-
IP degree of protectionIP2X
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V conforming to CSA C22.2 No 14
Operating altitude2000 m without derating
Ambient air temperature for operation-25…50 °C
Power pole contact composition2 NO + 2 NC
Hold-in power consumption in W3 W at 20 °C
Ambient air temperature for storage-50…80 °C
Utilisation categoryAC-1
Insulation resistance-
Heat dissipation1.3 W
Hold-in power consumption in VA-
Net weight0.225 kg
Minimum switching current-
Mounting supportPrinted circuit boards
Operating time30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening25...35 ms coil energisation and NC opening15 ms coil de-energisation and NC closing
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Product or component typeContactor
Tightening torque-
Maximum operating rate3600 cyc/h
RangeTeSys
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz
Height58 mm
Motor power kW4 kW at 690 V AC 50/60 Hz AC-4
Inrush power in W3 W (at 20 °C)
[Uimp] rated impulse withstand voltage8 kV
Electrical durability0.16 Mcycles 20 A AC-1 at Ue <= 690 V
Device short nameLP1K
Talk to Our Engineer for Schneider 220V DC TeSys K Contactor LP1K090085MD with exclusive offers. Core System Specifications of LP1K090085MD are control circuit voltage [Uc] operates at 220 V DC, with a minimum switching voltage of -, ensuring responsive operation. It is suitable for both motor Resistive load applications. The control circuit type is DC standard, and the auxiliary contacts are - configuration, providing reliable switching. The sensor features a 4P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. The utilization categories include AC-1, making it suitable for a wide range of applications. Product or component type Contactor. Don't Miss Out on a Quote for your requirement of Schneider 220V DC TeSys K Contactor. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.