Many procurement teams check ELECTRIC-LC1G2654LSEA against Schneider VFD, Schneider Electric Lc1E1810M7 and Schneider Contactors Easy Tesys before signing purchase orders, verifying quality, compliance, and after-sales support availability.
LC1G2654LSEA: Schneider 385A 4 Pole Advanced Contactor
Technical Specifications of Schneider 385A 4 Pole Advanced Contactor LC1G2654LSEA:

| Power Dissipation Per Pole | 20 W AC-1 - Ith 385 A11 W AC-3 - Ith 265 A |
| Range of Product | TeSys Giga |
| Pole Contact Composition | 4 NO |
| Connection Terminals | Power circuit: bar 2 - busbar cross section: 32 x 10 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end |
Schneider 385A 4 Pole Advanced Contactor LC1G2654LSEA Technical Specifications:
| Specification | Value |
|---|---|
| Device short name | LC1G |
| Power dissipation per pole | 20 W AC-1 - Ith 385 A11 W AC-3 - Ith 265 A |
| Ambient air temperature for operation | -25…60 °C |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz<= 460 V DC |
| Range of product | TeSys Giga |
| Rated breaking capacity | 2380 A at 440 V |
| Auxiliary contact composition | 1 NO + 1 NC |
| Maximum operating rate | 600 cyc/h AC-3600 cyc/h AC-3e300 cyc/h AC-1 |
| Width | 185 mm |
| Poles description | 4P |
| Utilisation category | AC-3AC-3eAC-1AC-5aAC-5bAC-6aAC-6bDC-1DC-3DC-5 |
| Colour | Dark grey |
| Control circuit voltage limits | Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C)Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C) |
| Motor power hp | - |
| Height | 290 mm |
| Mechanical durability | 8 Mcycles |
| [Ie] rated operational current | 265 A (at <60 °C) at <= 440 V AC-3385 A (at <40 °C) at <= 1000 V AC-1 |
| Operating time | 40...70 ms closing15...50 ms opening |
| Pole contact composition | 4 NO |
| Ambient air temperature for storage | -60…80 °C |
| Product or component type | Contactor |
| [Uc] control circuit voltage | 200...500 V AC 50/60 Hz200...500 V DC |
| Tightening torque | 35 N.m |
| Depth | 226 mm |
| Associated fuse rating | 315 A aM at <= 440 V for motor250 A aM at <= 690 V for motor400 A gG at <= 690 V |
| [Icw] rated short-time withstand current | 2.2 kA - 10 s1.23 kA - 30 s0.95 kA - 1 min0.62 kA - 3 min0.48 kA - 10 min |
| Motor power kW | - |
| Net weight | 8.7 kg |
| IP degree of protection | IP2X front face with shrouds conforming to IEC 60529IP2X front face with shrouds conforming to VDE 0106 |
| hold-in power consumption in W (DC) | 9.0 W |
| Range | TeSys |
| Connections - terminals | Power circuit: bar 2 - busbar cross section: 32 x 10 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5…1.0 mm² with cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Mounting support | Plate |
| Connection pitch | 45 mm |
| [Ui] rated insulation voltage | 1000 V |
Ask for the Pricing of Schneider 385A 4 Pole Advanced Contactor LC1G2654LSEA at unbeatable prices. Detailed Specifications of LC1G2654LSEA features device short name LC1G, designed for efficient power management in industrial applications. The sensor has a power dissipation per pole of 20 W AC-1 - Ith 385 A11 W AC-3 - Ith 265 A, ensuring energy-efficient operation. It operates within a broad ambient temperature range of -25…60 °C, making it suitable for various environmental conditions. The rated operational voltage [Ue] is up to <= 1000 V AC 50/60 Hz<= 460 V DC, providing robust power handling. Its rated breaking capacity reaches 2380 A at 440 V, ensuring reliable performance during switching. The auxiliary contact composition includes 1 NO + 1 NC, enhancing flexibility in control applications. With the mechanical durability of 8 Mcycles, the sensor guarantees long-lasting reliability. Operating times include a closing time of 40...70 ms closing15...50 ms opening quick and responsive operation. Now's the Time to Secure a Quote for your requirement of Schneider 385A 4 Pole Advanced Contactor . We're committed to offering more favorable pricing and more responsive support than other Traders.