Schneider LC1E40B10F7 Contactor
Technical Specifications of Schneider Easy TeSys Contactor 40A 110V AC Coil LC1E40B10F7:

| Product Component Type | Contactor |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| Power Dissipation Per Pole | 2.9 W AC-35 W AC-1 |
| Tightening Torque | Control circuit: 1.2 N.mPower circuit: 2.1 N.m |
Schneider LC1E40B10F7 Contactor – Technical Specifications
| Specification | Value |
|---|---|
| Range | Easy TeSys |
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Motor power kW | 18.5 kW at 500 V18.5 kW at 660...690 V9 kW at 220...230 V AC 50/60 Hz18.5 kW at 380...400 V18.5 kW at 415 V18.5 kW at 440 V |
| Pole contact composition | 3 NO |
| Irms rated making capacity | 400 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 320 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 60 A 40 °C - 600 s for power circuit310 A 40 °C - 10 s for power circuit150 A 40 °C - 60 s for power circuit |
| Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-163 A gG at <= 690 V coordination type 1 for power circuit |
| Power dissipation per pole | 2.9 W AC-35 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Control circuit type | AC at 50/60 Hz |
| Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz |
| Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C)95 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 8.5 VA 50 Hz cos phi 0.3 (at 20 °C)8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W for control circuit |
| Operating time | 12...22 ms on closing4...19 ms on opening |
| Maximum operating rate | 1800 cyc/h 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end |
| Tightening torque | Control circuit: 1.2 N.mPower circuit: 2.1 N.m |
| Auxiliary contact composition | 1 NO |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Mounting support | PlateDIN rail |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Height | 84 mm |
| Width | 56 mm |
| Depth | 86 mm |
| Net weight | 0.45 kg |
Mail Us for your needs in Schneider Easy TeSys Contactor 40A 110V AC Coil LC1E40B10F7 with budget-friendly prices. The Main Technical Parameters of LC1E40B10F7 include Easy TeSys Control Range of products and the Contactor Product or component type 3P, designed for efficient performance in Power circuit: <= 690 V AC 50/60 Hz. This product features a rated operational current of 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit. It operates at a control circuit voltage of 110 V AC 50/60 Hz, with 3 NO poles. The convenCustomize Your Experience with a Quote for your requirement of Schneider Easy TeSys Contactor 40A 110V AC Coil. Experience the difference with our competitive pricing and superior support over other Suppliers.