+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

GZ1E06: Schneider Thermomagnetic Breaker GZ1 3 Pole

Technical Specifications of Schneider Thermomagnetic Breaker GZ1 3 Pole GZ1E06:

Mounting SupportRail
Power Dissipation2.5 W (per pole)
Mounting ModeBy screwsBy clips
Connections TerminalsScrew clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end

Schneider Thermomagnetic Breaker GZ1 3 Pole GZ1E06 Technical Specifications:

SpecificationValue
Device applicationMotor
mounting positionAny position
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Ambient air temperature for operation-20…60 °C
Mounting supportRail
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Electrical durability100000 cycles for AC-3
RangeEasy TeSys
Magnetic tripping current22.5 A
Product or component typeCircuit breaker
poles description3P
Width44.5 mm
Control typePush-button
IP degree of protectionIP20 conforming to IEC 60529
ColourGrey (RAL 7011)
Power dissipation2.5 W (per pole)
mounting modeBy screwsBy clips
Operating altitude2000 m
Fire resistance960 °C conforming to IEC 60695-2-1
Thermal protection adjustment range1…1.6 A
Net weight0.26 kg
Motor power kW0.37 kW at 400 V AC 50/60 Hz0.55 kW at 440 V AC 50/60 Hz0.75 kW at 500 V AC 50/60 Hz1.1 kW at 690 V AC 50/60 Hz
Network typeAC
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Device short nameGZ1E
Utilisation categoryAC-3
Maximum operating rate25 cyc/h
Range of productEasy TeSys Power
Ambient air temperature for storage-40…80 °C
Network frequency50/60 Hz conforming to IEC 60947-2
Depth78 mm
Trip unit technologyThermal-magnetic
Height89 mm
Connections - terminalsScrew clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end
Obtain a Quote for Schneider Thermomagnetic Breaker GZ1 3 Pole GZ1E06 at economical prices. Specifications Overview for GZ1E06 reveals Motor applications, suitable for installation in Any position. It has a rated impulse to withstand voltage [Uimp] of 6 kV conforming to IEC 60947-2 standards, ensuring robust protection. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C and can be mounted on a Rail for flexible installation. Its rated operational voltage [Ue] is 690 V AC 50/60 Hz conforming to IEC 60947-2, providing reliable power handling. With the electrical durability of 100000 cycles for AC-3 applications, this sensor ensures long-lasting performance. The magnetic tripping current is set at 22.5 A, and it features a 3P configuration. Take the First Step with a Quote for your requirement of Schneider Thermomagnetic Breaker GZ1 3 Pole. Our commitment to better pricing and exceptional support sets us apart from other Competitors.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.