Many engineers reviewing Schneider ELECTRIC-GZ1E03 also explore Schneider VFD, Schneider Electric Lc1E1810M7 and Schneider Contactors Easy Tesys, ensuring they don’t miss strong alternatives before finalizing procurement decisions.
GZ1E03: Schneider GZ1 0.25-0.40A Circuit Breaker
Technical Specifications of Schneider GZ1 0.25-0.40A Circuit Breaker GZ1E03:

| Mounting Support | Rail |
| Power Dissipation | 2.5 W (per pole) |
| Mounting Mode | By clipsBy screws |
| Connections Terminals | Screw clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end |
Schneider GZ1 0.25-0.40A Circuit Breaker GZ1E03 Technical Specifications:
| Specification | Value |
|---|---|
| Device application | Motor |
| mounting position | Any position |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Ambient air temperature for operation | -20…60 °C |
| Mounting support | Rail |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Electrical durability | 100000 cycles for AC-3 |
| Range | Easy TeSys |
| Magnetic tripping current | 5 A |
| Product or component type | Circuit breaker |
| poles description | 3P |
| Width | 44.5 mm |
| Control type | Push-button |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Colour | Grey (RAL 7011) |
| Power dissipation | 2.5 W (per pole) |
| mounting mode | By clipsBy screws |
| Operating altitude | 2000 m |
| Fire resistance | 960 °C conforming to IEC 60695-2-1 |
| Thermal protection adjustment range | 0.25…0.4 A |
| Net weight | 0.26 kg |
| Motor power kW | - |
| Network type | AC |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Device short name | GZ1E |
| Utilisation category | AC-3 |
| Maximum operating rate | 25 cyc/h |
| Range of product | Easy TeSys Power |
| Ambient air temperature for storage | -40…80 °C |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Depth | 78 mm |
| Trip unit technology | Thermal-magnetic |
| Height | 89 mm |
| Connections - terminals | Screw clamp terminals 2 1…6 mm² - cable stiffness: solidScrew clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end |
Ask for the Pricing of Schneider GZ1 0.25-0.40A Circuit Breaker GZ1E03 at unbeatable prices. Detailed Specifications of GZ1E03 features Motor applications, suitable for installation in Any position. It has a rated impulse to withstand voltage [Uimp] of 6 kV conforming to IEC 60947-2 standards, ensuring robust protection. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C and can be mounted on a Rail for flexible installation. Its rated operational voltage [Ue] is 690 V AC 50/60 Hz conforming to IEC 60947-2, providing reliable power handling. With the electrical durability of 100000 cycles for AC-3 applications, this sensor ensures long-lasting performance. The magnetic tripping current is set at 5 A, and it features a 3P configuration. Now's the Time to Secure a Quote for your requirement of Schneider GZ1 0.25-0.40A Circuit Breaker. We're committed to offering more favorable pricing and more responsive support than other Traders.