If you’re not fully sure about ELECTRIC-ATV610D90N4, taking a closer look at Lenze Drive, Schneider Modicon M580 PLC and Magelis HMI Software often helps compare reliability, cost, and availability.
Schneider ATV610D90N4 Variable Speed Drive
The Schneider ATV610D90N4 is a high-performance variable speed drive (VSD) designed for 3-phase motor control. With a powerful motor power of 90 kW (125 hp), it is ideal for demanding applications like pumps, fans, and compressors.

| Brand | Schneider |
| Product Type | VFD - Variable Frequency Drive |
| Model Number | ATV610D90N4 |
Schneider ATV610D90N4 Variable Speed Drive – Technical Specifications
| Specification | Value |
|---|---|
| Mounting mode | Cabinet mount |
| Height | 762 mm922 mm with EMC plate |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Range of product | Easy Altivar 610 |
| Ambient air temperature for operation | -15…45 °C (without derating)45…60 °C (with derating factor) |
| Communication port protocol | Modbus serial |
| Operating position | Vertical +/- 10 degree |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output |
| Product destination | Asynchronous motorsSynchronous motors |
| IP degree of protection | IP20 |
| number of preset speeds | 16 preset speeds |
| Line current | 177.8 A at 380 V (normal duty)159.9 A at 460 V (normal duty)155.8 A at 380 V (heavy duty)138.1 A at 460 V (heavy duty) |
| Braking to standstill | By DC injection |
| Number of Units in Package 2 | - |
| Analogue input number | 3 |
| Output voltage | <= power supply voltage |
| Analogue output type | Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Depth | 323 mm |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 sS, U or customized |
| Product specific application | Fan, pump, compressor, conveyor |
| Continuous output current | 173 A at 2.5 kHz for normal duty145 A at 2.5 kHz for heavy duty |
| Apparent power | 127.4 kVA at 460 V (normal duty)110.0 kVA at 460 V (heavy duty) |
| Product or component type | Variable speed drive |
| Width | 290 mm |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Maximum transient current | 190 A during 60 s (normal duty)218 A during 60 s (heavy duty) |
| Physical interface | 2-wire RS 485 for Modbus serial |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| Discrete input type | DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Ambient air temperature for storage | -40…70 °C |
| Noise level | 78 dB conforming to 86/188/EEC |
| Relay output number | 3 |
| Discrete input logic | Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Relay Output Type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Net Weight | 53 kg |
| Motor power hp | 125 hp for normal duty100 hp for heavy duty |
| Electrical connection | Control, screw terminal: 0.5...1.5 mm²Line side, screw terminal: 95...120 mm²Motor, screw terminal: 95...120 mm² |
| Transmission frame | RTU for Modbus serial |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Analogue output number | 2 |
| Switching frequency | 1...8 kHz adjustable |
| Motor power kW | 90 kW for normal duty75 kW for heavy duty |
| Supply frequency | 50...60 Hz +/-5 % |
| Output frequency | 0.1…500 Hz |
| Protection type | Thermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive |
| Type of cooling | Forced convection |
The ATV610D90N4 delivers an impressive 90 kW (125 HP) output for normal duty and 75 kW (100 HP) for heavy duty, ensuring powerful torque control with a continuous output current of 173 A at 2.5 kHz. This model supports an output frequency range of 0.1–500 Hz and operates seamlessly at 50–60 Hz ±5% input supply. The integrated IP20 protection, EMC filter (IEC 61800-3 Category C3), and cabinet-mount design enhance durability in demanding industrial conditions. With a height of 762 mm (922 mm with EMC plate), width of 290 mm, and depth of 323 mm, it offers compact installation for high-capacity motor drives.
This Schneider 125 HP VFD features a 2-wire RS-485 Modbus serial communication interface for easy integration into PLC and SCADA systems. It includes 3 analog inputs (0–10 V / 0–20 mA), 2 analog outputs, and 6 programmable digital inputs supporting logic or pulse signals up to 30 kHz, ensuring precise process control and flexibility. The drive’s braking by DC injection enables quick motor stopping, while its adjustable acceleration and deceleration ramps (0.01–9000 s) offer smooth operation for fans, pumps, and conveyors. It also maintains consistent performance from –15 °C to +60 °C and relative humidity up to 95%, conforming to IEC 60068-2-3 standards.
Engineered for reliability, the ATV610D90N4 includes complete protection features—thermal overload, short-circuit, phase loss, under/overvoltage, and overspeed protection. The built-in cooling system uses forced convection for stable operation under continuous load. Noise levels are maintained below 78 dB for quiet functioning in enclosed panels. Electrical connections use screw terminals from 0.5 to 120 mm², supporting both control and motor-side wiring. Its proven design minimizes downtime and extends the lifespan of connected motors, ensuring long-term efficiency in critical automation systems.
The Schneider ATV610D90N4 is designed for high-capacity systems where precision motor speed control is essential. In HVAC and building management, it optimizes fan and compressor performance, reducing energy consumption and maintaining temperature stability. In water treatment facilities, it controls pumps to prevent hydraulic shocks, stabilize pressure, and enable remote monitoring through Modbus communication. For industrial conveyors and compressors, the VFD ensures smooth torque delivery and protects motors from start-stop stress.
Maintenance engineers and automation professionals prefer the ATV610D90N4 for its easy installation, simple configuration, and dependable performance under heavy-duty operation. Its ability to control both asynchronous and synchronous motors gives it versatility across diverse industries such as manufacturing, process automation, and utilities. The user-friendly interface and accurate analog feedback simplify setup, making it equally useful for junior engineers, plant supervisors, and training institutions that teach modern motor control techniques.
By integrating the Schneider ATV610D90N4 into your control system, you ensure consistent productivity, optimized energy use, and maximum motor protection. Its combination of robust design, intuitive control, and digital communication capabilities makes it one of the most reliable VFDs for Indian industrial applications today.
If you’re looking for detailed insights on the Schneider 125 HP VFD, explore the official ATV610D90N4 datasheet and ATV610D90N4 manual for wiring, parameters, and performance details. The ATV610D90N4 offers outstanding value for high-load industrial systems, with strong after-sales and technical support. To get the latest ATV610D90N4 price or connect with verified Schneider distributors, request a quote through IndMALL and ensure you receive authentic products with expert assistance.