Schneider ATV610D30N4 Variable Speed Drive
Schneider ATV610D30N4 is a high-capacity 40 HP Variable Frequency Drive (VFD) designed for precise motor control in heavy-duty industrial applications.

| Brand | Schneider |
| Product Type | VFD - Variable Frequency Drive |
| Model Number | ATV610D30N4 |
Schneider ATV610D30N4 Variable Speed Drive – Technical Specifications
| Specification | Value |
|---|---|
| Mounting mode | Cabinet mount |
| Height | 613 mm706 mm with EMC plate |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Range of product | Easy Altivar 610 |
| Ambient air temperature for operation | -15…45 °C (without derating)45…60 °C (with derating factor) |
| Communication port protocol | Modbus serial |
| Operating position | Vertical +/- 10 degree |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output |
| Product destination | Asynchronous motorsSynchronous motors |
| IP degree of protection | IP20 |
| number of preset speeds | 16 preset speeds |
| Line current | 62.5 A at 380 V (normal duty)55.8 A at 460 V (normal duty)49.7 A at 380 V (heavy duty)42.5 A at 460 V (heavy duty) |
| Braking to standstill | By DC injection |
| Number of Units in Package 2 | - |
| Analogue input number | 3 |
| Output voltage | <= power supply voltage |
| Analogue output type | Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Depth | 271 mm |
| Acceleration and deceleration ramps | S, U or customizedLinear adjustable separately from 0.01 to 9000 s |
| Product specific application | Fan, pump, compressor, conveyor |
| Continuous output current | 61.5 A at 4 kHz for normal duty46.3 A at 4 kHz for heavy duty |
| Apparent power | 44.5 kVA at 460 V (normal duty)33.8 kVA at 460 V (heavy duty) |
| Product or component type | Variable speed drive |
| Width | 226 mm |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Maximum transient current | 67.7 A during 60 s (normal duty)69.5 A during 60 s (heavy duty) |
| Physical interface | 2-wire RS 485 for Modbus serial |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| Discrete input type | DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Ambient air temperature for storage | -40…70 °C |
| Noise level | 75 dB conforming to 86/188/EEC |
| Relay output number | 3 |
| Discrete input logic | Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Relay Output Type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Net Weight | 25.5 kg |
| Motor power hp | 40 hp for normal duty30 hp for heavy duty |
| Electrical connection | Control, screw terminals: 0.5...1.5 mm²Line side, screw terminal: 25...50 mm²Motor, screw terminal: 25...50 mm² |
| Transmission frame | RTU for Modbus serial |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Analogue output number | 2 |
| Switching frequency | 2...12 kHz adjustable |
| Motor power kW | 30 kW for normal duty22 kW for heavy duty |
| Supply frequency | 50...60 Hz +/-5 % |
| Output frequency | 0.1…500 Hz |
| Protection type | Thermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive |
| Type of cooling | Forced convection |
The Schneider ATV610D30N4 is a robust VFD for 3-phase, 40HP industrial motor control—engineered to optimize energy use, stabilize torque, and simplify commissioning across pumps, fans, compressors, and conveyors in demanding automation environments.
Engineered for plant reliability, the ATV610D30N4 (Easy Altivar 610) delivers 30kW (40HP) in normal duty and 22kW (30HP) in heavy duty with continuous currents of 61.5A (ND, 4kHz) and 46.3A (HD, 4kHz). Designed for cabinet mounting, it carries an IP20 rating and compact dimensions—H 613mm (706mm with EMC plate), W 226mm, D 271mm—at a manageable 25.5kg. Precision control comes from an output frequency of 0.1…500Hz, 2…12kHz switching, 16 preset speeds, and independently adjustable acceleration/deceleration ramps from 0.01…9000s. Three analog inputs (0–10V / 0–20mA), two analog outputs, and six digital inputs support both asynchronous and synchronous motors, while RS-485 Modbus RTU with RJ45 ensures seamless PLC/SCADA integration and diagnostics.
Built for harsh duty, this Schneider 40HP VFD 3Phase operates from −15…60°C and up to 95% RH (IEC60068-2-3), includes an integrated EMC filter (IEC61800-3 CatC3), and keeps acoustics in check at 75dB. Comprehensive protections—thermal (motor/drive), overcurrent, short-circuit, over/undervoltage, DC-bus overvoltage, phase loss, overspeed, and control-circuit break—safeguard uptime, while configurable relays (3×, 3A) simplify interlocking and alarms. For wiring ranges from 0.5…50mm², commissioning is straightforward, making the ATV610D30N4 a dependable choice for utilities, water handling, HVAC, and process lines seeking long service life and lower total cost of ownership. Review the ATV610D30N4 datasheet and ATV610D30N4 manual or request the latest ATV610D30N4 price to specify with confidence.