Schneider ATV610D18N4 Variable Speed Drive
The Schneider Altivar 610 18.5kW Variable Speed Drive ATV610D18N4 is a high-efficiency VFD built for modern industrial automation needs.

| Brand | Schneider |
| Product Type | VFD - Variable Frequency Drive |
| Model Number | ATV610D18N4 |
Schneider ATV610D18N4 Variable Speed Drive – Technical Specifications
| Specification | Value |
|---|---|
| Mounting mode | Cabinet mount |
| Height | 495 mm580 mm with EMC plate |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Range of product | Easy Altivar 610 |
| Ambient air temperature for operation | -15…45 °C (without derating)45…60 °C (with derating factor) |
| Communication port protocol | Modbus serial |
| Operating position | Vertical +/- 10 degree |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output |
| Product destination | Asynchronous motorsSynchronous motors |
| IP degree of protection | IP20 |
| number of preset speeds | 16 preset speeds |
| Line current | 37.2 A at 380 V (normal duty)33.5 A at 460 V (normal duty)31.6 A at 380 V (heavy duty)28.3 A at 460 V (heavy duty) |
| Braking to standstill | By DC injection |
| Number of Units in Package 2 | 4 |
| Analogue input number | 3 |
| Output voltage | <= power supply voltage |
| Analogue output type | Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Depth | 232 mm |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 sS, U or customized |
| Product specific application | Fan, pump, compressor, conveyor |
| Continuous output current | 39.2 A at 4 kHz for normal duty31.7 A at 4 kHz for heavy duty |
| Apparent power | 26.7 kVA at 460 V (normal duty)22.6 kVA at 460 V (heavy duty) |
| Product or component type | Variable speed drive |
| Width | 211 mm |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Maximum transient current | 43.1 A during 60 s (normal duty)47.6 A during 60 s (heavy duty) |
| Physical interface | 2-wire RS 485 for Modbus serial |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| Discrete input type | DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Ambient air temperature for storage | -40…70 °C |
| Noise level | 65 dB conforming to 86/188/EEC |
| Relay output number | 3 |
| Discrete input logic | Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Relay Output Type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Net Weight | 13.5 kg |
| Motor power hp | 25 hp for normal duty20 hp for heavy duty |
| Electrical connection | Control, screw terminals: 0.5...1.5 mm²Line side, screw terminal: 10...16 mm²Motor, screw terminal: 10...16 mm² |
| Transmission frame | RTU for Modbus serial |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Analogue output number | 2 |
| Switching frequency | 2...12 kHz adjustable |
| Motor power kW | 18.5 kW for normal duty15 kW for heavy duty |
| Supply frequency | 50...60 Hz +/-5 % |
| Output frequency | 0.1…500 Hz |
| Protection type | Thermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive |
| Type of cooling | Forced convection |
The Schneider ATV610D18N4 is a compact VFD from the Easy Altivar 610 range, engineered for 18.5kW (25HP) three-phase motor control in pumps, fans, compressors, and conveyors—delivering soft starts, precise speed/torque, and energy savings for industrial automation.
Built for dependable plant operation, the ATV610D18N4 provides 18.5kW (ND) / 15kW (HD) with continuous output currents of 39.2A (ND, 4kHz) and 31.7A (HD, 4kHz), plus line currents up to 37.2A at 380V (ND). The cabinet-mount design is IP20 and compact—H 495mm (580mm with EMC plate), W 211mm, D 232mm—at 13.5kg, suiting space-constrained panels. Engineers get fine control via an output frequency of 0.1…500Hz, 2…12kHz switching, 16 preset speeds, and independently adjustable ramps (0.01…9000s). I/O is sensor-ready: 3 analog inputs (0–10V / 0–20mA, including temperature/level probes), 2 analog outputs, 6 digital inputs (pulse to 30kHz), and 3 relay outputs (3A, 100k cycles) for interlocks/alarms. A 2-wire RS-485 Modbus RTU interface with RJ45 ensures seamless PLC/SCADA integration and diagnostics.
Trusted in harsh environments, this Schneider drive operates from −15…60°C and up to 95% RH (IEC60068-2-3), includes an integrated EMC filter (IEC61800-3 CatC3), and maintains a low 65dB noise profile. Comprehensive protections—thermal (motor/drive), overcurrent, short-circuit, over/undervoltage, phase loss, overspeed, and DC-bus events—safeguard uptime while DC-injection braking shortens stops on critical lines. For wiring ranges (control 0.5…1.5mm², power 10…16;mm²) and quick commissioning, the ATV610D18N4 simplifies standardization across utilities, water handling, HVAC, and process plants. For configuration details, see the ATV610D18N4 datasheet.