Maintenance teams planning replacements for ELECTRIC-ATV610C11N4 frequently review Lenze Drive, Schneider Modicon M580 PLC and Magelis HMI Software to prevent downtime, checking availability and compatibility with existing systems.
Schneider ATV610C11N4 Variable Speed Drive
The Schneider ATV610C11N4 is a high-efficiency 110 kW Variable Speed Drive (VSD) engineered for three-phase industrial motor applications.

| Brand | Schneider |
| Product Type | VFD - Variable Frequency Drive |
| Model Number | ATV610C11N4 |
Schneider ATV610C11N4 Variable Speed Drive – Technical Specifications
| Specification | Value |
|---|---|
| Mounting mode | Cabinet mount |
| Height | 850 mm1161 mm with IP21 conformity kit |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Range of product | Easy Altivar 610 |
| Ambient air temperature for operation | -15…45 °C (without derating)45…60 °C (with derating factor) |
| Communication port protocol | Modbus serial |
| Operating position | Vertical +/- 10 degree |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output |
| Product destination | Asynchronous motorsSynchronous motors |
| IP degree of protection | IP20 |
| number of preset speeds | 16 preset speeds |
| Line current | 201 A at 380 V (normal duty)175.7 A at 460 V (normal duty)170 A at 380 V (heavy duty)149.1 A at 460 V (heavy duty) |
| Braking to standstill | By DC injection |
| Number of Units in Package 2 | - |
| Analogue input number | 3 |
| Output voltage | <= power supply voltage |
| Analogue output type | Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Depth | 375 mm |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 sS, U or customized |
| Product specific application | Fan, pump, compressor, conveyor |
| Continuous output current | 211 A at 2.5 kHz for normal duty173 A at 2.5 kHz for heavy duty |
| Apparent power | 140.0 kVA at 460 V (normal duty)118.8 kVA at 460 V (heavy duty) |
| Product or component type | Variable speed drive |
| Width | 300 mm |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Maximum transient current | 232 A during 60 s (normal duty)260 A during 60 s (heavy duty) |
| Physical interface | 2-wire RS 485 for Modbus serial |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| Discrete input type | DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Ambient air temperature for storage | - |
| Noise level | 76 dB conforming to 86/188/EEC |
| Relay output number | 3 |
| Discrete input logic | Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Relay Output Type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Net Weight | 85.5 kg |
| Motor power hp | 150 hp for normal duty125 hp for heavy duty |
| Electrical connection | Control, screw terminal: 0.5...1.5 mm²Line side, screw terminal: 2 x 50...3 x 120 mm²Motor, screw terminal: 3 x 50...3 x 120 mm² |
| Transmission frame | RTU for Modbus serial |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Analogue output number | 2 |
| Switching frequency | 1...8 kHz adjustable |
| Motor power kW | 110 kW for normal duty90 kW for heavy duty |
| Supply frequency | 50...60 Hz +/-5 % |
| Output frequency | 0.1…500 Hz |
| Protection type | Thermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive |
| Type of cooling | Forced convection |
Built for robust industrial performance, the ATV610C11N4 VFD delivers a rated motor power of 110 kW (150 HP) for normal duty and 90 kW (125 HP) for heavy duty operations. It supports a continuous output current of 211 A @ 2.5 kHz in normal duty, with peak transient current up to 260 A for demanding torque applications. The drive operates on a 380–460 V AC supply and provides an output frequency range of 0.1–500 Hz with adjustable 1–8 kHz switching frequency. Three analog inputs and two analog outputs allow flexible configuration for voltage (0–10 V) or current (0–20 mA) signals, enabling precise motor speed control and process feedback.
For communication, the Schneider ATV610C11N4 integrates an RS-485 Modbus serial interface that seamlessly connects with PLC and SCADA systems. It features 16 preset speeds, individually programmable acceleration and deceleration ramps (0.01 – 9000 s), and built-in DC injection braking for smooth motor stopping. The enclosure offers IP20 protection with an optional IP21 kit and an integrated EMC filter compliant with IEC 61800-3 Category C3 standards. Designed for ambient temperatures –15 °C to 60 °C and humidity up to 95 % non-condensing, the ATV610C11N4 is ideal for Indian industrial conditions. Weighing 85.5 kg, it ensures thermal stability and durability through forced-convection cooling and comprehensive drive protections (overcurrent, overvoltage, short circuit, phase loss, and motor thermal faults).
The Schneider ATV610C11N4 is widely used in HVAC systems, pumps, fans, compressors, and conveyor drives where precise speed regulation and energy optimization are critical. In water-treatment and irrigation plants, it enables soft starting and flow control, minimizing mechanical stress on motors and pipelines. In HVAC applications, it maintains balanced airflow and temperature while reducing energy consumption by adjusting motor speed automatically. Conveyor and material-handling lines benefit from its torque-controlled acceleration and deceleration, preventing belt wear and vibration. For compressors, the drive ensures stable pressure output under varying loads and reduces operational noise.
Engineers value the Schneider ATV610C11N4 for its reliability, quick response, and compatibility with modern automation systems. With Schneider’s Easy Altivar 610 VSD platform, maintenance teams gain simplified diagnostics and fault monitoring via the Modbus interface, helping reduce downtime. Whether deployed in factories, building management systems, or process industries, this 110 kW VFD stands out as a durable solution for improving motor efficiency and energy savings. The ATV610C11N4 is engineered to deliver consistent performance and long service life in Indian industrial conditions.