ATV340U75N4E - Schneider 15 HP VFD
Technical specificatons of Schneider 15 HP VFD ATV340U75N4E:

| Motor Power hp | 15 hp for normal duty10 hp for heavy duty |
| [Us] Rated Supply Voltage | 380...480 V - 15...10 % |
| Continuous Output Current | 24 A at 4 kHz for normal duty16.5 A at 4 kHz for heavy duty |
| Degree of Protection | - |
Schneider 15 HP VFD ATV340U75N4E Technical Specifications:
| Specification | Value |
|---|---|
| Analogue input number | 22 |
| Motor power hp | 15 hp for normal duty10 hp for heavy duty |
| Protection type | Thermal protection: motorSafe torque off: motorMotor phase loss: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent: driveOutput overcurrent between motor phase and earth: driveOutput overcurrent between motor phases: driveShort-circuit between motor phase and earth: driveShort-circuit between motor phases: driveMotor phase loss: driveDC Bus overvoltage: driveLine supply overvoltage: driveLine supply undervoltage: driveInput supply loss: driveExceeding limit speed: driveBreak on the control circuit: drive |
| Network number of phases | 3 phases |
| Electrical connection | DC bus: screw terminal 4...6 mm²/AWG 12...AWG 10Control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12Motor: screw terminal 1.5...6 mm²/AWG 14...AWG 10Line side: screw terminal 2.5...6 mm²/AWG 12...AWG 10 |
| Continuous output current | 24 A at 4 kHz for normal duty16.5 A at 4 kHz for heavy duty |
| Overvoltage category | Class III |
| Noise level | 46.5 dB |
| Analogue output number | 1 |
| Degree of protection | - |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3Class 3S3 according to IEC 60721-3-3 |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Standards | IEC 61800-3IEC 61800-5-1IEC 60721-3IEC 61508IEC 13849-1UL 618000-5-1UL 508C |
| Relay output number | 2 |
| Ambient air temperature for operation | -15…50 °C without derating (vertical position)50…60 °C with derating factor (vertical position) |
| Discrete input number | 5 |
| Product certifications | ULCSATÜVEACCTick |
| Type of cooling | Forced convection |
| Net weight | 3.0 kg |
| EMC filter | Class C3 EMC filter integrated |
| Communication port protocol | EtherNet/IPModbus serialModbus TCP |
| Supply frequency | 50...60 Hz +/- 5 % |
| Mounting mode | Cabinet mount |
| Discrete output number | 2 |
| Connector type | 3 RJ45 |
Request the Schneider 15 HP VFD ATV340U75N4E Price at unbeatable rates! Explore the ATV340U75N4E Datasheet to discover detailed specifications of this model, which includes motor power of 15 hp for normal duty and 10 hp for heavy duty. It features an adjustable switching frequency range of 2...16 kHz, adjustable to 4...16 kHz with a derating factor. The continuous output current is 24 A at 4 kHz for normal duty and 16.5 A at 4 kHz for heavy duty, with a maximum input current of 25.6 A. The output voltage matches the power supply voltage, ensuring compatibility across various systems. Part of the Altivar Machine ATV340 range, it operates on a supply frequency of 50...60 Hz +/- 5%. The sensor, designed for Cabinet mounting, uses a 2-wire RS 485 physical interface and includes 3 RJ45 connectors for seamless connectivity. Secure a custom quote for your requirement and request the ATV340U75N4E Manual to explore its full capabilities. Get more responsive support and favorable pricing compared to other traders!