In sourcing discussions, ELECTRIC-ATV310H037N4E is often placed next to Lenze Drive, Schneider Modicon M580 PLC and Magelis HMI Software so procurement teams can align budgets and technical requirements effectively.
Schneider ATV310H037N4E Variable Speed Drive
The Schneider ATV310H037N4E is a Heavy Duty VFD from the Easy Altivar 310 series, delivering precise motor control for industrial applications.

| Brand | Schneider |
| Product Type | VFD - Variable Frequency Drive |
| Model Number | ATV310H037N4E |
Schneider ATV310H037N4E Variable Speed Drive – Technical Specifications
| Specification | Value |
|---|---|
| Minimum switching current | 5 mA at 24 V DC for logic relay |
| Analogue output number | 1 |
| Height | 143 mm |
| Speed drive output frequency | 0.5…400 Hz |
| Unit Type of Package 2 | P12 |
| Time constant | 20 ms +/- 1 ms for reference change |
| Operating altitude | <= 1000 m without derating |
| Number of addresses | 1…247 for Modbus |
| Supply frequency | 50/60 Hz +/- 5 % |
| Device short name | ATV310 |
| Acceleration and deceleration ramps | Linear from 0...999.9 sSU |
| Speed range | 1…20 for asynchronous motor |
| Physical interface | 2-wire RS 485 for Modbus |
| Product or component type | Variable speed drive |
| Ambient air temperature for storage | -25…70 °C |
| Analogue input number | 1 |
| Output voltage | 380...460 V three phase |
| Continuous output current | 1.5 A heavy duty |
| Package 2 Weight | 70.000 kg |
| Asynchronous motor control profile | Voltage/frequency ratio (V/f)Voltage/frequency ratio - Energy Saving, quadratic U/fSensorless vector control (SVC) |
| Electrical connection | Terminal, clamping capacity: 1.5...2.5 mm², AWG 16...AWG 14 (L1, L2, L3, U, V, W) |
| Maximum switching current | 2 A at 250 V AC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay2 A at 30 V DC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay3 A at 250 V AC on resistive load cos phi = 1 L/R = 0 ms for logic relay4 A at 30 V DC on resistive load cos phi = 1 L/R = 0 ms for logic relay |
| Electromagnetic compatibility | Electrical fast transient/burst immunity test - test level: level 4 conforming to IEC 61000-4-4Electrostatic discharge immunity test - test level: level 3 conforming to IEC 61000-4-2Immunity to conducted disturbances - test level: level 3 conforming to IEC 61000-4-6Radiated radio-frequency electromagnetic field immunity test - test level: level 3 conforming to IEC 61000-4-3Voltage dips and interruptions immunity test conforming to IEC 61000-4-11Surge immunity test - test level: level 3 conforming to IEC 61000-4-5 |
| Motor slip compensation | Adjustable |
| Supply | Internal supply for reference potentiometer: 5 V (4.75…5.25 V)DC, <10 mA with overload and short-circuit protectionInternal supply for logic inputs: 24 V (20.4…28.8 V)DC, <100 mA with overload and short-circuit protection |
| Braking torque | Up to 70 % of nominal motor torque without braking resistor |
| Number of Units in Package 1 | 1 |
| Width | 72 mm |
| Package 1 Weight | 1.014 kg |
| Range of product | Easy Altivar 310 |
| Depth | 130 mm |
| Operating position | Vertical +/- 10 degree |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Communication service | Read holding registers (03) 29 wordsWrite single register (06) 29 wordsWrite multiple registers (16) 27 wordsRead/write multiple registers (23) 4/4 wordsRead device identification (43) |
| Quantity per set | Set of 1 |
The ATV310H037N4E from Schneider's Easy Altivar 310 series is a three-phase VFD rated for 380–460 V input and supports a continuous output current of 1.5 A (Heavy Duty). With a height of 143 mm, width of 72 mm, and depth of 130 mm, it is ideal for compact panels. The drive’s output frequency range of 0.5 to 400 Hz allows it to handle a wide range of motor speeds and load requirements.
This model supports sensorless vector control (SVC), energy-saving V/f control, and standard V/f motor control profiles. It features 1 analog input, 1 analog output, and a reliable 2-wire RS485 Modbus interface with address range 1 to 247, enabling seamless integration with PLCs and HMIs. With adjustable motor slip compensation, linear acceleration/deceleration ramps (0–999.9 s), and high EMC immunity (conforming to IEC 61000 standards), this VFD ensures stable operation in noisy electrical environments.
The ATV310H037N4E includes an internal 24 V DC supply for logic inputs and 5 V for potentiometer references, with built-in overload and short-circuit protection. Rated for up to 1000 m altitude without derating and storage between -25°C to 70°C, it's built to endure tough industrial conditions. Braking torque reaches up to 70% without external resistors. For wiring, it supports 1.5–2.5 mm² terminals and can handle switching currents up to 4 A at 30 V DC. The Schneider ATV310H037N4E is ideal for controlling small motors in fan, pump, and conveyor systems within manufacturing units, HVAC applications, and packaging lines. Its compact design and reliable motor torque delivery make it suitable for OEMs seeking cost-effective, plug-and-play motor control solutions.
Control engineers appreciate its ready-to-integrate Modbus RTU communication and energy-efficient design that reduces operational cost while maintaining high accuracy in variable load conditions. With excellent immunity to voltage surges, electrostatic discharge, and EMI, it’s a solid choice for industrial panels requiring consistent uptime. Whether you need a durable drive for small asynchronous motors or a smart automation-ready VFD, the Schneider Easy Altivar 310 Heavy Duty VFD ATV310H037N4E delivers performance, protection, and peace of mind in one compact unit.