+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

ATS480C41Y - Schneider 110 to 230V AC Control Supply

ATS480C41Y Datasheet covers all essential technical details of the Schneider ATS480C41Y Soft Starter, a powerful Variable Frequency Drive (VFD) with an operational current of 410A.

BrandSchneider
Product TypeVFD(Variable Frequency Drive)
ProductATS480C41Y

Schneider 110 to 230V AC Control Supply ATS480C41Y Technical Specifications:

SpecificationValue
Range of ProductAltivar Soft Starter ATS480
Motor power kW110.0 kW at 230 V in the motor supply line normal duty90.0 kW at 230 V in the motor supply line heavy duty220.0 kW at 400 V in the motor supply line normal duty160.0 kW at 400 V in the motor supply line heavy duty220.0 kW at 440 V in the motor supply line normal duty160.0 kW at 440 V in the motor supply line heavy duty250.0 kW at 500 V in the motor supply line normal duty220.0 kW at 500 V in the motor supply line heavy duty250.0 kW at 525 V in the motor supply line normal duty220.0 kW at 525 V in the motor supply line heavy duty355.0 kW at 660 V in the motor supply line normal duty250.0 kW at 660 V in the motor supply line heavy duty400.0 kW at 690 V in the motor supply line normal duty315.0 kW at 690 V in the motor supply line heavy duty220.0 kW at 230 V to the motor delta terminals normal duty160.0 kW at 230 V to the motor delta terminals heavy duty315.0 kW at 400 V to the motor delta terminals normal duty250.0 kW at 400 V to the motor delta terminals heavy duty
Rated operational current [Ie]Normal duty: 410.0 A (at <40 °C)
Torque controlTRUE
Rated insulation voltage [Ui]690 V
Minimum switching current100 mA at 12 V DC for relay outputs
Maximum switching currentRelay outputs 2 A at 250 V ACRelay outputs 2 A at 30 V DCRelay outputs
Power supply frequency50...60 Hz - 20...20 %
Method of accessSlave Modbus serial
Package weight60.0 kg
Discrete Output Type(DQ1) programmable digital output <= 30 V (DQ2) programmable digital output <= 30 V
Analog Output Number1
Maximum acceleration under vibratory load (during storage)15 m/s² at 200...500 Hz10 m/s² at 9...200 Hz
Device Short nameATS480
Net Weight51.4 kg
IP Degree protectionIP00
Output CompatibilityOpen collector level 1 PLC conforming to IEC 65A-68
[Uc] control circuit voltage24 V DC
Relay output number3
Discrete input logicProgrammable digital input at State 0: < 5 V
Communication port protocolModbus serial
Motor Power Hp125.0 hp at 208 V normal duty100.0 hp at 208 V heavy duty150.0 hp at 230 V normal duty125.0 hp at 230 V heavy duty300.0 hp at 460 V normal duty250.0 hp at 460 V heavy duty350.0 hp at 575 V normal duty300.0 hp at 575 V heavy duty
Relay Output TypeRelay outputs R1A 1 NORelay outputs R1B 1 NORelay outputs RIC NO/NC programmable
Ambient air temperature for operation40…60 °C (with current derating of 2 % per °C)-15…40 °C (without derating)
data format8 bits, configurable odd, even or no parity
Pollution DegreeLevel 3
Ambient air temperature for storage-25…70 °C
Relative Humidity0…95 % without condensation or dripping water conforming to IEC 60068-2-3
Width400.0 mm
Ue power supply voltage208...690 V - 15...10 %
Connection Type1 RJ45

Part of the advanced Altivar ATS480 series, the Schneider ATS480C41Y supports motor power up to 400 kW at 690 V in normal duty and 315 kW in heavy duty. It is suitable for direct connection to both the motor supply line and motor delta terminals, offering torque control, thermal protection, and smooth acceleration for heavy loads like crushers, blowers, and centrifugal pumps.

This soft starter features 3 relay outputs, 2 programmable digital outputs (≤30 V), 1 analog output, and operates on a 24 V DC control circuit. Communication is handled via Slave Modbus serial protocol through an RJ45 port. Rated insulation voltage is 690 V, and switching currents are rated at 2 A at 250 V AC or 2 A at 30 V DC, making it compatible with a variety of industrial control panels.

The ATS480C41Y is housed in a 400 mm wide IP00 enclosure with a net weight of 51.4 kg. It is built to withstand harsh environments with humidity up to 95% (non-condensing), operating temperatures from -15°C to 60°C, and vibratory loads up to 15 m/s². The Schneider ATS480C41Y Soft Starter is an ideal fit for applications in cement plants, HVAC systems, water pumping stations, and large-scale conveyor systems requiring high starting torque with smooth current ramp-up. It offers reliability, energy efficiency, and longevity for motors operating under challenging industrial conditions.

Engineers and panel builders choose this model for its broad voltage compatibility (208–690 V), robust build, and seamless integration via Modbus. Its ability to reduce mechanical stress during motor startup helps extend equipment life and reduce downtime in critical systems.

Contact us today to request a quote, download the ATS480C41Y manual, and secure the best ATS480C41Y Price with verified support from trusted industrial suppliers.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.