Maintenance teams planning replacements for ELECTRIC-ATS130N2D65LT frequently review Lenze Drive, Schneider Modicon M580 PLC and Magelis HMI Software to prevent downtime, checking availability and compatibility with existing systems.
ATS130N2D65LT: Schneider Altivar Soft Starter 24V DC
The ATS130N2D65LT is a high-capacity soft starter from Schneider Electric, part of the trusted Schneider Altivar Soft Starter ATS130 series.

| Brand | Schneider |
| Product Type | VFD(Variable Frequency Drive) |
| Product | ATS130N2D65LT |
Schneider Altivar Soft Starter 24V DC ATS130N2D65LT Technical Specifications:
| Specification | Value |
|---|---|
| Power supply frequency | 50...60 Hz +/- 5 Hz |
| Operating cycles/hour | 13 cyc/h |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Height | 166 mm |
| Relay output number | 1 |
| Display type | 1 LED (green) for control power energized1 LED (yellow and red) for motor operation phases, errors |
| Pollution degree | Level 2 |
| Minimum motor current | 20 % Ie |
| Protection type | Phase failure: mainsThermal protection: starterBypass error: starterControl voltage Us: starter |
| Package 1 Length | 28.000 cm |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Environmental class (during operation) | Without salt mist: 3C3 conforming to IEC 60721-3-33S3 conforming to IEC 60721-3-3 |
| Suitable for mounting onto standard rails | TRUE |
| Overload current profile | 300 % Ie for 5 s |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Function available | Deceleration voltage rampBoost |
| Minimum switching current | 2.5 mA at 24 V DC for relay outputs |
| Operating altitude | 0...1000 m without derating1000...4000 m 1 % per 100 m |
| Package 1 Weight | 1.512 kg |
| Motor power hp | 20 hp at 200 V normal duty20 hp at 208 V normal duty20 hp at 230 V normal duty40 hp at 460 V normal duty50 hp at 480 V normal duty |
| IP degree of protection | IP20 |
| Ambient air transport temperature | -40…70 °C |
| Product or component type | Soft starter |
| Utilisation category | AC-53A |
| Ue power supply voltage | 200...480 V - 15...10 % |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cyclesOn resistive load for relay outputs : 1 A 30 V DC 400000 cyclesOn inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cyclesOn inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Depth | 165 mm |
| Operating position | Vertical +/- 30 degree |
| [Ui] rated insulation voltage | 480 V |
| Network number of phases | 3 phases |
| Input compatibility | Discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Device connection | In line |
| Width | 55 mm |
| Torque control | FALSE |
| Ambient air temperature for storage | -25…70 °C |
| Control power | 21.6 W starting and stopping3 W steady state |
| Range of product | Altivar Soft Starter ATS130 |
| [Uc] control circuit voltage | 24 V DC |
| Relative humidity | 5…95 % non condensing without dripping water conforming to IEC 60068-2-3 |
| Power loss per device current dependent | 16 W |
| Net weight | 1.3 kg |
| [Ie] rated operational current | 65 A in line (at <40 °C) |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Ambient air temperature for operation | -10…40 °C (without derating)40…60 °C (with current derating 1.5 % per °C) |
| Motor power kW | 18.5 kW at 230 V normal duty30 kW at 400 V normal duty37 kW at 440 V normal duty |
| Power loss static current independent | 3 W |
| Power loss during starting | 397 W 300 % Ie |
| Relay output type | Relay outputs R1A, R1C NO |
| Number of Units in Package 1 | 1 |
The Schneider ATS130N2D65LT supports a 3-phase power supply ranging from 200 to 480 V, operating at 50–60 Hz ±5%, and provides a rated operational current of 65 A at temperatures up to 40°C. It is capable of handling motor power ratings up to 37 kW at 440 V or 30 kW at 400 V, making it suitable for medium- to heavy-duty industrial loads.
The unit features 1 relay output (R1A, R1C NO) and provides protection against phase failure, thermal overload, and bypass errors. The control circuit voltage is 24 V DC, and it supports PLC-level discrete input compatibility as per EN/IEC 61131-2. With a compact footprint of 166 mm (H) x 55 mm (W) x 165 mm (D) and net weight of 1.3 kg, the soft starter can be installed vertically within ±30° in tight control cabinets.
Environmentally, the ATS130N2D65LT conforms to IEC 60721-3-3 standards, operates safely in -10°C to 60°C, and tolerates up to 4000 m altitude with derating. It consumes 3 W at steady state and 397 W during motor startup at 300% Ie, with low power loss and efficient design.The Schneider Altivar Soft Starter model ATS130N2D65LT is ideal for controlling industrial motors in applications like water pumping stations, compressors, crushers, material handling systems, and high-torque HVAC equipment. The built-in voltage ramp and boost functions ensure smooth acceleration and deceleration, reducing mechanical wear and extending equipment life.
Automation engineers benefit from its easy DIN-rail mounting, robust relay output performance, and seamless integration with PLC systems. With protection against high vibration, overload, and environmental variations, this soft starter ensures stable performance in critical industrial operations.
For businesses seeking a reliable 65 A starter with 24 V DC control, the ATS130N2D65LT offers high power, flexible control, and Siemens-backed durability—now available at unmatched pricing and faster delivery through IndMALL Automation across India.