Reer SR XM Safety Light Curtain
The Reer SR XM Safety Light Curtain offers Type 2 - PL c safety level, 2 NO (6A at 250 VAC) safety relay outputs, Removable terminal blocks. screw contacts. Manufactured by Reer Safety under the Reer Safety Light Curtain category, this model belongs to the SR Series.

| Brand | Reer Safety |
| Product Type | Safety Interface |
| Model Number | SR XM |
Reer SR XM Safety Light Curtain – Technical Specifications
| Specification | Value |
|---|---|
| Safety level | Type 2 - PL c |
| Safety level (SIL / PL) | Type 2 - SILCL 1 - PL c - Cat. 2 |
| Operating temperature (°C) | - 30 ... 55 |
| Response time (ms) | ≤ 20 |
| Signalling | LEDs indication of power on. connected photocells status. Muting sensors status. Muting status. Override status and fault diagnosis |
| Connections | Removable terminal blocks. screw contacts |
| MTTFD (ISO13849) years | The values depend on the type of use. Refer to the technical manual |
| PFHD (IEC 61508) | The values depend on the type of use. Refer to the technical manual |
| Safety devices to be connected | Ilion and Ulisse safety photocell |
| Safety relay outputs | 2 NO (6A at 250 VAC) |
| Product class | C |
| Power supply (VDC) | 24 ± 20% |
| Dimensions HxWxD (mm) | 99 x 35 x 114 |
| Degree of protection | IP2X |
| Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
| Packaging dimensions HxLxW (mm) | 57 x 158 x 134 |
| Custom tariff | 85365080 |
| Gross weight (g) | 258.3 |
| Start/Restart | Automatic/Manual monitored selectable |
| Muting logic | L (One way) logic with 2 sensors - Crossed beams |
| Muting timeout | Selectable: 30 sec. or infinite |
| Muting inputs | 2 at 24 VDC - PNP or relay - dark on |
Reach Us by Email for Reer Safety Relays to connect Safety Photocell SR XM part no: 1201711 at Discounted Rates. Key Technical Features of SR XM, 1201711 are These interfaces meet Type 2 - SILCL 1 - PL c - Cat. 2 standards, ensuring top-tier protection. Operating in temperatures from - 30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication of power on. connected photocells status. Muting sensors status. Muting status. Override status and fault diagnosis and use Removable terminal blocks. screw contacts. They are compatible with Ilion and Ulisse safety photocell The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 35 x 114, they operate at 24 ± 20% and offer IP2X protection. Navigate Your Needs with a Quote for your requirement of Reer Safety Relays to connect Safety Photocell. Our pricing and support are unrivaled, especially when compared to other Competitors.