Reer SR XC Safety Light Curtain
The Reer SR XC Safety Light Curtain offers Type 2 - PL c safety level, 2 NO (6A at 250 VAC) safety relay outputs, Removable terminal blocks. clamp contacts. Manufactured by Reer Safety under the Reer Safety Light Curtain category, this model belongs to the SR Series.

| Brand | Reer Safety |
| Product Type | Safety Interface |
| Model Number | SR XC |
Reer SR XC Safety Light Curtain – Technical Specifications
| Specification | Value |
|---|---|
| Safety level | Type 2 - PL c |
| Safety level (SIL / PL) | Type 2 - SILCL 1 - PL c - Cat. 2 |
| Operating temperature (°C) | -30 ... 55 |
| Response time (ms) | ≤ 20 |
| Signalling | LEDs indication of power on. connected photocells status and fault diagnosis |
| Connections | Removable terminal blocks. clamp contacts |
| MTTFD (ISO13849) years | The values depend on the type of use. Refer to the technical manual |
| PFHD (IEC 61508) | The values depend on the type of use. Refer to the technical manual |
| Safety devices to be connected | Ilion and Ulisse safety photocell |
| Safety relay outputs | 2 NO (6A at 250 VAC) |
| Product class | C |
| Power supply (VDC) | 24 ± 20% |
| Dimensions HxWxD (mm) | 99 x 22.5 x 114.5 |
| Degree of protection | IP2X |
| Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
| Packaging dimensions HxLxW (mm) | 57 x 158 x 134 |
| Custom tariff | 85365080 |
| Gross weight (g) | 186.8 |
| Start/Restart | Automatic/Manual monitored selectable |
Send Your Inquiry for Reer Type 2 Cat 2 Safety Level Safety Relays SR XC part no: 1201714 with cost-effective solutions. Essential Technical Specs of SR XC, 1201714 are These interfaces meet Type 2 - SILCL 1 - PL c - Cat. 2 standards, ensuring top-tier protection. Operating in temperatures from -30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication of power on. connected photocells status and fault diagnosis and use Removable terminal blocks. clamp contacts. They are compatible with Ilion and Ulisse safety photocell The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 22.5 x 114.5, they operate at 24 ± 20% and offer IP2X protection. Capture the Best Deal with a Quote for your requirement of Reer Type 2 Cat 2 Safety Level Safety Relays. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.