Procurement managers rarely finalize PHOENIX-CONTACT-URTK-BEN without reviewing SMPS Phoenix, Phoenixcontact Phoenix Contact Mtk P P and Wago Terminal Blocks, ensuring that the chosen component meets budget, compliance, and delivery conditions.
Phoenix Contact URTK-BEN - 309112 - Disconnect terminal block
Technical Specifications of Disconnect terminal block URTK-BEN 309112
| Brand | Phoenix Contact |
| Product Type | Terminal Block |
| Product | URTK-BEN |
Phoenix Contact Disconnect terminal block URTK-BEN, 309112 Technical Specifications
| Specification | Value |
|---|---|
| Product type | Disconnect terminal block |
| DIN rail/fixing support | NS 32 |
| Number of connections | 2 |
| Number of rows | 1 |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 6 kV |
| Maximum power dissipation for nominal condition | 1.82 W |
| Number of connections per level | 2 |
| Nominal cross section | 10 mmΓΒ² |
| Stripping length | 8 mm |
| Connection in acc. with standard | IEC 6094771 |
| Conductor cross section rigid | 0.5 mmΓΒ² ... 16 mmΓΒ² |
| Cross section AWG | 20 ... 6 (converted acc. to IEC) |
| Conductor cross section flexible | 0.5 mmΓΒ² ... 10 mmΓΒ² |
| Conductor cross section, flexible [AWG] | 20 ... 8 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mmΓΒ² ... 10 mmΓΒ² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mmΓΒ² ... 10 mmΓΒ² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mmΓΒ² ... 6 mmΓΒ² |
| Nominal current | 57 A |
| Maximum load current | 70 A |
| Nominal voltage | 500 V |
| Width | 10.2 mm |
| Height | 61 mm |
| Depth on NS 35/7,5 | 58.5 mm |
| Depth on NS 35/15 | 66 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | 60 ΓΒ°C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 ΓΒ°C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Test voltage setpoint | 1.89 kV |
| Result | Test passed |
| Requirement temperature-rise test | Increase in temperature Γ’ΒΒ€ 45 K |
| Open side panel | Yes |
| Rotation speed | 10 (+/ 2) rpm |
| Revolutions | 135 |
| Conductor cross section/weight | 0.5 mmΓΒ² / 0.3 kg |
| Time of exposure | 30 s |
| Ambient temperature (operation) | 60 ΓΒ°C ... 110 ΓΒ°C (Operating temperature range incl. selfheating; for max. shortterm operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | 25 ΓΒ°C ... 60 ΓΒ°C (for a short time, not exceeding 24 h, 60 ΓΒ°C to +70 ΓΒ°C) |
| Ambient temperature (assembly) | 5 ΓΒ°C ... 70 ΓΒ°C |
| Ambient temperature (actuation) | 5 ΓΒ°C ... 70 ΓΒ°C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | NS 35/7,5 |
| Screw thread | M3 |
| Tightening torque | 1.5 ... 1.8 Nm |
| 2 conductors with same cross section, solid | 0.2 mmΓΒ² ... 4 mmΓΒ² |
| 2 conductors with same cross section, flexible | 0.2 mmΓΒ² ... 4 mmΓΒ² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mmΓΒ² ... 6 mmΓΒ² |
| Depth on NS 32 | 63.5 mm |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 ΓΒ°C |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Tightening torque disconnect slide | M3 0.6 ... 0.8 Nm |
| Short-time withstand current 10 mmΓΒ² | 1.2 kA |