Procurement teams shortlist PHOENIX-CONTACT-PT-4-PE-L-MT with SMPS Phoenix, Phoenixcontact Phoenix Contact Mtk P P and Wago Terminal Blocks, aligning budget approvals, warranty terms, and multisite availability for smoother rollout across plants.
Phoenix Contact PT 4-PE/L/MT - 3002617 - Ground terminal block
Technical Specifications of Ground terminal block PT 4-PE/L/MT 3002617

| Brand | Phoenix Contact |
| Product Type | Terminal Block |
| Product | PT 4-PE/L/MT |
Phoenix Contact Ground terminal block PT 4-PE/L/MT, 3002617 Technical Specifications
| Specification | Value |
|---|---|
| Product type | Ground terminal block |
| DIN rail/fixing support | NS 35/15 |
| Number of connections | 5 |
| Number of rows | 3 |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 6 kV |
| Maximum power dissipation for nominal condition | 1.02 W |
| Number of connections per level | 2 |
| Nominal cross section | 4 mm² |
| Stripping length | 10 mm ... 12 mm |
| Internal cylindrical gage | A4 |
| Connection in acc. with standard | IEC 6094773 |
| Conductor cross section rigid | 0.5 mm² ... 6 mm² |
| Cross section AWG | 24 ... 10 (converted acc. to IEC) |
| Conductor cross section flexible | 0.2 mm² ... 4 mm² |
| Conductor cross section, flexible [AWG] | 24 ... 10 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.5 mm² ... 4 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² ... 4 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1 mm² |
| Nominal current | 20 A |
| Maximum load current | 20 A (6 mm²) |
| Nominal voltage | 500 V |
| Width | 6.2 mm |
| Height | 119.5 mm |
| Depth on NS 35/7,5 | 57.6 mm |
| Depth on NS 35/15 | 65.1 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | 60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Test voltage setpoint | 1.89 kV |
| Result | Test passed |
| Requirement temperature-rise test | Increase in temperature ⤠45 K |
| Short-time withstand current 2.5 mm² | 0.3 kA |
| Short-time withstand current 4 mm² | 0.48 kA |
| Open side panel | Yes |
| DIN rail/fixing support | NS 35 |
| Test force setpoint | 1 N |
| Rotation speed | 10 rpm |
| Revolutions | 135 |
| Conductor cross section/weight | 0.2 mm² / 0.2 kg |
| Temperature cycles | 192 |
| Time of exposure | 30 s |
| Ambient temperature (operation) | 60 °C ... 110 °C (Operating temperature range incl. selfheating; for max. shortterm operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | 25 °C ... 60 °C (for a short time, not exceeding 24 h, 60 °C to +70 °C) |
| Ambient temperature (assembly) | 5 °C ... 70 °C |
| Ambient temperature (actuation) | 5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | NS 35/7,5 |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Specification | DIN EN 50155 (VDE 0115200):200803 |
| Spectrum | Long life test category 1, class B, body mounted |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| ASD level | 0.964 (m/s²)²/Hz |
| Acceleration | 5g |
| Test duration per axis | 5 h |
| Test directions | X, Y and Zaxis (pos. and neg.) |
| Pulse shape | Halfsine |
| Shock duration | 30 ms |
| Number of shocks per direction | 3 |
| Rated cross section AWG | 12 |
| Depth | 54.5 mm |
| Product family | PT |
| Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve) | 0.5 mm² ... 1 mm² |
| Short-time withstand current 6 mm² | 0.72 kA |
| output | (Permanent) |
| Identification | X II 3 G Ex ec llC Gc |
| Operating temperature range | 60 °C ... 125 °C |
| Operating cycles of the disconnect knife | 100 |
| Ex-certified accessories | 3002619 DPT 4PE/L/HESI |
| List of bridges | Plugin bridge / FBS 26 / 3030336 |
| Bridge data | 19 A / 4 mm² |
| Rated voltage | 275 V |
| Rated current | 20 A (4 mm²) |
| Contact resistance | 1.7 mΩ |
| Connection capacity rigid | 0.2 mm² ... 6 mm² |
| Connection capacity AWG | 24 ... 12 |
| Connection capacity flexible | 0.2 mm² ... 4 mm² |
| Conductor cross section, rigid [AWG] | 20 ... 10 (converted acc. to IEC) |
| Rated insulation voltage | 250 V |
| Temperature increase | 35 K (20 A/4 mm²) |
| - At bridging between non-adjacent terminal blocks | 275 V |
| - At cut-to-length bridging with cover | 275 V |