Many engineers reviewing Phoenixcontact PHOENIX-CONTACT-PSR-SCP-24DC-ESD-5X1-1X2-300 also explore SMPS Phoenix, Sick Safety Relay and Phoenixcontact Phoenix Contact Psr Scp 24Uc Esl4 3X1 1X2 B, ensuring they donโt miss strong alternatives before finalizing procurement decisions.
Phoenix Contact PSR-SCP-24DC/ESD/5X1/1X2/300 - 2981428 - Safety relays
Technical Specifications of Safety relays PSR-SCP-24DC/ESD/5X1/1X2/300 2981428

| Brand | Phoenix Contact |
| Product Type | Safety Relays |
| Product | PSR-SCP-24DC/ESD/5X1/1X2/300 |
Phoenix Contact Safety relays PSR-SCP-24DC/ESD/5X1/1X2/300, 2981428 Technical Specifications
| Specification | Value |
|---|---|
| Note on application | Only for industrial use |
| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Emergency stop |
| Control | 1 and 2 channel |
| Mechanical service life | 10x 106 cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Typical response time | < 600 ms (automatic start) |
| Typ. starting time with Us | < 600 ms (when controlled via A1) |
| Typical release time | < 20 ms (when controlled via S11/S12 and S21/S22) |
| Recovery time | < 1 s |
| Maximum power dissipation for nominal condition | 3.72 W |
| Nominal operating mode | 100% operating factor |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV: between all current paths and housing Safe isolation, reinforced insulation 6 kV: between 13/14, 23/24, 33/34, and the remaining current paths between 13/14, 23/24, 33/34 among one another |
| Inrush current | 200 mA (at US) |
| Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
| Max. permissible overall conductor resistance | approx. 22 ฮฉ (Input and start circuits at US) |
| Protective circuit | Surge protection; Suppressor diode |
| Current consumption | < 40 mA (with Us/Ix to S10) |
| Contact switching type | 5 enabling current paths |
| Contact material | AgSnO2 |
| Limiting continuous current | 6 A (N/O contact, pay attention to the derating) |
| Sq. Total current | 55 A2 (observe derating) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, ฯ = 0 ms) |
| Maximum interrupting rating (inductive load) | 42 W (24 V DC, ฯ = 40 ms, delayed contacts: 48 W) |
| Output fuse | 10 A gL/gG (N/O contact) |
| pluggable | yes |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mmยฒ ... 2.5 mmยฒ |
| Conductor cross section flexible | 0.2 mmยฒ ... 2.5 mmยฒ |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Status display | 4 x LED (green) |
| Operating voltage display | 1 x LED (green) |
| Width | 45 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | PBT |
| Category | 4 (Undelayed contacts) |
| Performance level (PL) | e (for delayed contacts PL d) |
| Safety Integrity Level (SIL) | 3 (for delayed contacts SIL 2) |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 ยฐC ... 55 ยฐC (observe derating) |
| Ambient temperature (storage/transport) | -40 ยฐC ... 70 ยฐC |
| Maximum altitude | โค 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Rated control supply current IS | typ. 155 mA |
| Power consumption at US | typ. 3.72 W |
| Concurrence | โ |
| Voltage at input/start and feedback circuit | 24 V DC -15 % / +10 % |
| Maximum switching frequency | 0.5 Hz |
| Maximum switching voltage | 250 V AC/DC (Observe the load curve) |
| Minimum switching voltage | 5 V AC/DC |
| Maximum inrush current | 20 A (ฮt ยฃ 100 ms, undelayed contacts) |
| Inrush current, minimum | 10 mA |
| Switching capacity min. | 50 mW |
| Switching capacity (360/h cycles) | 4 A (24 V DC) |
| Switching capacity (3600/h cycles) | 2.5 A (24 V (DC13)) |
| Certificate | CE-compliant |