Before procurement teams confirm KCD2-SCD-EX1, they typically review P&F Photoelectric Sensor, Pepperl Fuchs Kfd2 Stc5 Ex2 and Pepperl Fuchs Double Sheet Sensors to double-check performance ratings, stock availability, and supplier credibility carefully.
Pepperl Fuchs KCD2-SCD-Ex1 Current Driver
The Pepperl Fuchs KCD2-SCD-Ex1 Current Driver offers a Analog output signal type, SIL 2, and screw terminals connection. Manufactured by Pepperl Fuchs under the P&F Current Driver category.

| Brand | Pepperl Fuchs |
| Product Type | Intrinsic Safety Barrier |
| Model Number | KCD2-SCD-Ex1 |
Pepperl Fuchs KCD2-SCD-Ex1 Current Driver β Technical Specifications
| Specification | Value |
|---|---|
| Signal type | Analog output |
| Safety Integrity Level (SIL) | SIL 2 |
| Rated voltage | 19 ... 30 V DC |
| Control circuit Connection | - |
| Control circuit Voltage | - |
| Control circuit Current | - |
| Field circuit Connection | - |
| Field circuit Voltage | - |
| Field circuit Current | - |
| Influence of ambient temperature | < 2 Β΅A/K (0 ... 60 Β°C (32 ... 140 Β°F)); < 4 Β΅A/K (-20 ... 0 Β°C (-4 ... 32 Β°F)) |
| Damping | - |
| Rise time | 10 to 90 % β€ 100 ms |
| Galvanic isolation Input/Output | reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff |
| Conformity Electromagnetic compatibility | NE 21 |
| Conformity Degree of protection | IEC 60529 |
| Ambient temperature | -20 ... 60 Β°C (-4 ... 140 Β°F) |
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
| EU-type examination certificate | CESI 06 ATEX 021 |
| Certificate | PF 06 CERT 0973 X |
Please speak to our Technical Engineer for P&F 12.5 mm Housing Width Current Drivers KCD2-SCD-Ex1 at attractive prices. Technical Specs Summary of KCD2-SCD-Ex1 includes - and operates on a - and - ratings. The device has a 770 ms response time and utilizes reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff. It complies with -20 ... 60 Β°C (-4 ... 140 Β°F) standards, operates in temperatures from -20 ... 60 Β°C (-4 ... 140 Β°F) and has an screw terminals rating. The unit mounts on a 77 mm DIN rail and weighs approximately 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2, with dimensions of CESI 06 ATEX 021. Match Your Needs with a Quote for your requirement of P&F 12.5 mm Housing Width Current Drivers. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.