Omron WLCA2-LE-N Limit Switch

Omron WLCA2-LE-N uses an R38 mm roller lever with screw terminals and a G½ conduit connection. A neon lamp provides an operation indicator, while pretravel is specified at 15±5°. The source lists a 5 VDC, 1 mA resistive minimum load and lamp operation from 125 to 250 VAC. IP67 protection, 100 MΩ minimum insulation resistance, and 25 mΩ maximum initial contact resistance are specified. The WLCA2-LE-N belongs to the WL Series within the R38 roller lever switch range from Omron switching products. The neon indicator and screw-terminal connection distinguish this version.

Omron WLCA2-LE-N Limit Switch
BrandOmron
ProductLimit Switch
Model NumberWLCA2-LE-N

Omron WLCA2-LE-N Limit Switch – Technical Specifications

SpecificationValue
Terminal ShapeScrew terminals (Conduit size: G½)
Pretravel Pt15±5°
Minimum Applicable Load5 VDC 1 mA, resistive load, P level
Rated Voltage125 to 250 VAC
Leakage Current Reference ValueApprox. 0.6 mA at 125 VAC Approx. 1.9 mA at 250 VAC
IndicatorNeon lamp (With operation indicator)
Ambient Temperature-10 to +80°C (with no icing)
Ambient Humidity35 to 95%RH
Shock ResistanceDestruction: 1,000 m/s2 min. Malfunction: 300 m/s2 min.
Degree Of ProtectionIP67
Insulation Resistance100 MΩ min. (at 500 VDC)
ActuatorRoller lever: R38 mm
Vibration ResistanceMalfunction: 10 to 55 Hz, 1.5-mm double amplitude
Contact Resistance25 mΩ max. (initial value for the built-in switch)
Rated Frequency50/60 Hz

The Omron WLCA2-LE-N Limit Switch uses an R38 mm roller lever together with screw terminals and a G½ conduit entry. Pretravel is specified at 15±5°. A neon lamp provides an operation indicator and is listed for 125 to 250 VAC, with approximate lamp currents of 0.6 mA at 125 VAC and 1.9 mA at 250 VAC. The minimum applicable load is 5 VDC at 1 mA for a resistive load at P level. IP67 protection, 100 MΩ minimum insulation resistance at 500 VDC, and 25 mΩ maximum initial contact resistance are specified.

Operating temperature covers -10 to 80°C with 35 to 95% relative humidity. Malfunction vibration resistance is 10 to 55 Hz at 1.5 mm double amplitude. Shock resistance is listed at 1,000 m/s² minimum for destruction and 300 m/s² minimum for malfunction. The fixed R38 lever and neon indication distinguish this version from adjustable or LED-equipped WL models. For an adjustable rod-lever model with LED indication and the same G½ screw-terminal format, see the WLCL-2NLD-N.