Omron TL-W5MD2 2M is a flat inductive proximity sensor with an unshielded sensing face, 5 mm sensing distance, and DC 2-wire NC output. It uses a pre-wired 2 m cable and operates from 12 to 24 VDC. The model is specified for ferrous-metal detection with an iron 18 × 18 × 1 mm standard sensing object, 500 Hz response frequency, 3 to 100 mA control-output load current, and 10% max. differential travel. A red operation indicator is provided together with load short-circuit protection, surge suppression, and IP67 protection. The TL-W5MD2 belongs to the Proximity sensor range from Omron industrial sensors.

Omron TL-W5MD2 2M Proximity Sensor
BrandOmron
ProductProximity Sensors
Model NumberTL-W5MD2 2M

Omron TL-W5MD2 2M Proximity Sensor - Technical Specifications

SpecificationValue
SensorFlat Inductive
Sensing Distance5 mm
Setting Distance0 to 4 mm
Output ConfigurationDC 2-Wire
Operation ModeNC
ConnectionPre-wired 2 M Cable
Differential Travel10% max. of sensing distance
Detectable ObjectFerrous metal
Standard Sensing ObjectIron, 18 × 18 × 1 mm
Response Frequency500 Hz
Control Output Load Current3 to 100 mA
IndicatorOperation indicator (red)
Protection CircuitLoad short-circuit protection, Surge suppressor
Ambient Temperature RangeOperating/Storage: −25 to 70°C (with no icing or condensation)
Ambient Humidity RangeOperating/Storage: 35% to 95% (with no condensation)
MaterialHeat-resistant ABS
Degree Of ProtectionIP67
WeightApprox. 80 g

The Omron TL-W5MD2 2M Proximity Sensor uses a flat inductive, unshielded sensing configuration with a 5 mm sensing distance and a 0 to 4 mm setting distance. Its electrical arrangement is DC 2-wire with NC operation, connected through a pre-wired 2 m cable. The model operates from 12 to 24 VDC. Ferrous metal is the specified detectable object, while an iron 18 × 18 × 1 mm target is used as the standard sensing object. Response frequency is 500 Hz, differential travel is 10% max. of sensing distance, and the control-output load current is specified from 3 to 100 mA. A red indicator displays operation status, with load short-circuit protection and a surge suppressor included.

Operating and storage temperature is specified from -25 to 70°C without icing or condensation, while operating and storage humidity is 35% to 95% without condensation. Heat-resistant ABS is listed as the construction material and the sensor carries an IP67 degree of protection. These specifications distinguish the TL-W5MD2 2M by its unshielded 5 mm sensing arrangement, DC 2-wire circuit, normally closed operation, and 2 m cable connection. Within the TL-W family, a related model retains the 5 mm unshielded sensing format while changing to normally open operation and a longer cable: TL-W5MD1 5M.